100 t电炉水冷炉壁的改造  

IMPROVEMENT OF WATER COOLING WALL OF 100 t ELECTRIC FURNACE

在线阅读下载全文

作  者:刘军海[1] 何庆兵[2] 王江波[2] Liu Junhai;He Qingbing;Wang Jiangbo(Anyang Iron and Steel Stock Co.,Ltd)

机构地区:[1]安阳钢铁股份有限公司第一炼轧厂,河南安阳455000 [2]安阳钢铁股份有限公司,河南安阳455000

出  处:《河南冶金》2020年第3期43-46,共4页Henan Metallurgy

摘  要:针对电炉装有集束氧枪的水冷炉壁在冶炼过程中经常被氧枪氧流反射烧漏水的问题,提出了相应的改进措施。通过去除水冷炉壁氧枪铜盘下方水冷管的方案,彻底解决了氧枪氧流反射烧漏水冷炉壁的问题,提高了电炉水冷炉壁的使用寿命。In view of the problem that the water-cooled furnace wall equipped with cluster oxygen gun is often burned and leaked by the oxygen gun during smelting process,the corresponding improvement measures are put forward.By removing all the water-cooled tubes under the copper plate of the oxygen lance,the problem of the oxygen lance refluxing and leaking the water-cooled furnace wall is solved thoroughly,and the service life of the water-cooled furnace wall of the electric furnace is improved.

关 键 词:水冷炉壁 集束氧枪 漏水 改造 

分 类 号:TF748.4[冶金工程—钢铁冶金]

 