作 者:张新勇[1] 王成钢[1] 甄雷[1] 师树田[1] 赵雪东 Zhang Xinyong;Wang Chenggang;Zhen Lei;Shi Shutian;Zhao Xuedong(Emergency Critical Care Center,Beijing Anzhen Hospital,Capital Medical University,Beijing Institute of Heart Lung and Blood Vessel Diseases,Beijing 100029,China)
机构地区:[1]首都医科大学附属北京安贞医院急诊危重症中心,北京市心肺血管病研究所,100029
出 处:《中国医药》2020年第8期1201-1203,共3页China Medicine
基 金:北京市科技计划(Z141107002514014)。
摘 要:目的评价两种血管闭合装置Exo Seal血管封堵器与Perclose血管缝合器在经皮冠状动脉介入治疗中应用的效果和安全性。方法收集2018年1—6月首都医科大学附属北京安贞医院收治的122例经股动脉行冠状动脉介入治疗患者的临床资料。诊疗术中分别采用Exo Seal血管封堵器(Exo Seal组,58例)和Perclose血管缝合器(Perclose组,64例)方法对股动脉穿刺点止血。记录并比较2组患者封堵成功率、操作时间、止血时间、制动时间、外周血管并发症。结果2组患者封堵成功率和制动时间比较,差异均无统计学意义(均P>0.05)。Exo Seal组操作时间和止血时间均明显短于Perclose组[(2.33±0.18)min比(4.15±0.40)min、(4.36±0.27)min比(6.91±0.43)min],差异均有统计学意义(均P<0.01)。2组外周血管并发症发生率比较,差异无统计学意义(P>0.05)。结论两种血管闭合装置止血用于冠状动脉介入诊治术后,并发症少,安全有效,其中Exoseal血管封堵器的操作更加简便。Objective To evaluate the safety and efficacy of Exo Seal vascular closure and Perclose vascular suture device in percutaneous coronary intervention(PCI).Methods From January to June 2018 clinical data of122 patients undergoing coronary intervention through the femoral artery admitted to Beijing Anzhen Hospital,Capital Medical University were collected.Exo Seal blood vessel occluder(Exo Seal group,58 cases)and Perclose blood vessel suture(Perclose group,64 cases)were used.The success rate of occlusion,operation time,hemostasis time,braking time and peripheral vascular complications were compared between the two groups.Results There were no significant differences in occlusion success rate and braking time between the two groups(both P>0.05).The operation time and hemostasis time in Exo Seal group were significantly shorter than those in Perclose group[(2.33±0.18)min vs(4.15±0.40)min,(4.36±0.27)min vs(6.91±0.43)min,both P<0.01].There was no significant difference in the incidence of peripheral vascular complications between the two groups(P>0.05).Conclusion The use of Exo Seal vascular closure and Perclose vascular suture device have good effects and safety in patients undergoing PCI.
关 键 词:经皮冠状动脉介入 ExoSeal封堵器 PERCLOSE血管缝合器
分 类 号:R541[医药卫生—心血管疾病]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.229