插拔装置液压系统压力异常故障分析与处理  被引量:2

Analysis and Treatment on Abnormal Pressure Fault of Plug-out Device Hydraulic System

在线阅读下载全文

作  者:吕明亮[1] 陈奇[1] 李玉顺[1] 张凌东 LV Ming-liang;CHEN Qi;LI Yu-shun;ZHANG Ling-dong(Beijing Space Launch Technology Institute,Beijing 100076,China)

机构地区:[1]北京航天发射技术研究所,北京100076

出  处:《液压气动与密封》2020年第9期58-60,共3页Hydraulics Pneumatics & Seals

摘  要:某插拔装置在进行调试时,出现了径向油缸正腔压力异常升高导致的问题。该文对故障原因进行分析,对可能出现的故障点进行排查,最终定位了故障点为某型号外购电液换向阀,故障原因为阀芯的非对称结构导致回油阻力过大。对于故障点,利用AMESim进行故障注入仿真,验证了故障分析的准确性并提出了解决措施,并经试验验证,故障定位准确,问题得以解决。During the commissioning of a plug-out device,the abnormal increase of pressure in the positive chamber of the radial cylinder occurred.In this paper,the causes of the failure are analyzed,and the possible fault points are checked.Finally,the fault point is located as a certain type of electro-hydraulic reversing valve.The reason for the failure is that the asymmetric structure of the valve core leads to excessive oil return resistance.For the fault point,AMESim is used to simulate the fault injection,which verifies the accuracy of fault analysis and proposes solutions.The test results show that the fault location is accurate and the solutions are effective.

关 键 词:插拔装置 压力异常 液压系统 分析与处理 

分 类 号:TH137[机械工程—机械制造及自动化]

 