锈蚀后间断式开孔钢板连接件的抗剪性能  被引量:3

Shear resistance of corroded discontinuous perfobond rib connections

在线阅读下载全文

作  者:张建东[1,2] 毛泽亮 叶遇春 刘朵[2] 邓文琴 顾建成 ZHANG Jiandong;MAO Zeliang;YE Yuchun;LIU Duo;DENG Wenqin;GU Jiancheng(College of Civil Engineering, Nanjing Tech University, Nanjing 211800, China;Jiangsu Transportation Research Institute Co. Ltd., Nanjing 210017, China;The Expressway Operation & Administration Center of Jiangsu Province, Nanjing 210049, China)

机构地区:[1]南京工业大学土木工程学院,江苏南京211800 [2]苏交科集团股份有限公司,江苏南京210017 [3]江苏省高速公路经营管理中心,江苏南京210049

出  处:《南京工业大学学报(自然科学版)》2020年第5期600-607,共8页Journal of Nanjing Tech University(Natural Science Edition)

基  金:国家自然科学基金(51778288,5190828);江苏省高等学校自然科学研究计划(19KJB580002);江苏省交通运输科技项目(2018Y11)。

摘  要:为研究锈蚀对新型剪力连接件抗剪性能的影响,本文利用外加电流加速锈蚀法对间断式开孔钢板连接件进行快速锈蚀处理,以设计锈蚀率为变量设计3组共6个推出试件,并利用有限元模型分别就开孔钢板与贯穿筋的锈蚀对连接件抗剪性能的影响进行研究。结果表明:在锈蚀率较低时,开孔钢板的锈蚀会增大接触面的黏结力,从而提高结构的初始刚度与极限承载力;随着锈蚀率进一步增加,结合面产生的锈胀裂缝导致钢混之间的黏结失效,连接件抗剪性能大幅降低;贯穿筋在锈蚀率达到10%时,连接件极限承载力仅下降5%,初始刚度几乎无衰减。To study the effect of corrosion on the shear resistance of new type shear connectors,a rapid corrosion treatment of discontinuous perfobond rib connectors was carried out by using the accelerated corrosion method of applied current.Three groups of 6 push-out specimens were designed with design corrosion rate as variable.Then the effects of corrosion of perfobond and transverse rebar on shear resistance of joints were studied by using finite element model.Results showed that when the corrosion rate was low,the corrosion of the perfobond would increase the bonding force of the contact surface,thus improving the initial stiffness and ultimate bearing capacity of the structure.With the further increase in the corrosion rate,the expansion cracks on the contact surface lead to the bonding failure between steel and concrete,and the shear resistance of the structure was sharply reduced.When the corrosion rate of the transverse rebar reached 10%,the ultimate bearing capacity of the connection decreased by only 5%,and the initial stiffness hardly decreased.

关 键 词:组合梁桥 间断式开孔钢板连接件 推出试验 锈蚀 抗剪承载力 

分 类 号:TU317.1[建筑科学—结构工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象