检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:刘畅[1] 万水娥[1] 贺克瑾[1] 王祎[1] Liu Chang;Wan Shui'e;He Kejin;Wang Yi(Beijing Institute of Architectural Design,Beijing,China;不详)
机构地区:[1]北京市建筑设计研究院有限公司
出 处:《暖通空调》2020年第9期79-82,110,共5页Heating Ventilating & Air Conditioning
摘 要:介绍了北京市地方标准DB 11/891—2012《居住建筑节能设计标准》修编中耗热量指标的选取方法与原则。提出了外表系数的概念,将围护结构热工参数规定性指标及能耗指标改为按照建筑外表系数进行分级。修编后耗热量指标改为采用能耗模拟软件进行动态逐时模拟计算,对耗热量指标提出了引导值与现行值,并提出了建筑朝向和南向窗墙面积比2个修正系数。Presents the selection method and principle of index of heat loss in the revision of Beijing local standard DB 11/891-2012 Design standard for energy efficiency of residential buildings.Puts forward the concept of surface factor,and changes the thermal parameter prescriptive indicators of building envelope and energy consumption indicators to be classified according to the building surface factor.After the revision,the index of heat loss should be calculated using the dynamic hourly simulation method.Proposes the guiding value and current value of the index of heat loss,and gives two correction coefficients of building orientation and south-facing window-wall area ratio.
关 键 词:居住建筑 节能设计标准 耗热量指标 外表系数 模拟