太原市三给水源地TS7#供水井污染原因分析  

Analyzing the Pollution Causes of the TS7 Water Supply Well in Taiyuan Sangei Water Source Field

在线阅读下载全文

作  者:王松[1] WANG Song

机构地区:[1]山西省水利水电勘测设计研究院有限公司,山西太原030024

出  处:《山西水利科技》2020年第3期11-13,31,共4页Shanxi Hydrotechnics

摘  要:文中通过配置不同添加物、不同浊度的模拟水样进行水质分析,对比高压灌浆中浆液的成分,分析二者之间的相似性、关联性,判断水源井中的污染物、污染源;通过分析水下高清电视、水源井成井结构,初步判断污染物进入水源井的部位;通过示踪试验确定水源井内、外之间的水力连通性,从而确定水源井内的污染途径。In this paper,water quality analysis is performed by simulating water samples with different kinds of additive and turbidity,comparing the components of the slurry in high-pressure grouting,analyzing the similarity and correlation between the two,and judging the pollutants and pollution sources in the water source well. By means of analyzing the structure of the underwater high-definition television and water source wells to determine the locations where pollutants enter the water source wells and to determine the hydraulic connectivity between the inside and outside of the water source wells through tracer tests,the pollution pathways in the water source wells are determined.

关 键 词:井下电视 示踪试验 高压灌浆 

分 类 号:TU991[建筑科学—市政工程]

 