检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:王美兰 WANG Meilan
出 处:《计量与测试技术》2020年第9期106-107,共2页Metrology & Measurement Technique
摘 要:李氏比重瓶在工程上应用广泛,随着科技的发展,粉体比重测定过程中对李氏比重瓶的容量示值的准确度要求越来越高,因此试验前对李氏比重瓶进行校正变得十分必要。本文基于衡量法,对李氏比重瓶的校准方法进行研究探讨,并通过建立测量模型,进行了不确定度分析。Pycnometer have been widely used in engineering.W ith the development of science and technology,the requirements of the accuracy of quantity of pycnometers'capacity have become more and more important,in the de-termination of specific gravity of powders.So,it has been very necessary to calibrate pycnometer before experi-ment.This paper was based on the measurement method,to study the calibration method of pycnometer,and by building the mathematical model to evaluate the uncertainty of measurement.
分 类 号:TB938.3[一般工业技术—计量学]