某型12kW自发电系统常见故障分析及处理  

Analysis and Treatment of Common Faults in a 12 kW Generating System

在线阅读下载全文

作  者:韩俊 赵立锋 HAN Jun;ZHAO Li-feng(Institute of China Electronics Technology Corporation,Jiaxing,314001)

机构地区:[1]中国电子科技集团公司第三十六研究所,嘉兴314001

出  处:《移动电源与车辆》2020年第3期59-64,共6页Movable Power Station & Vehicle

摘  要:某型12 kW自发电系统无法正常供电,本文通过对自发电系统电子调速器不升速和取力器无输出,两个典型故障进行了研究分析,并建立了故障树,为用户在自发电系统遇到故障时,能做出及时的判断和应对措施提供帮助。The power supply of a 12 KW self-generating power system is not normal. Through the research and analysis of the two typical faults of the self-generating power system, the electronic governor does not raise speed and the force taker does not output, and the fault tree is established to provide help for users to make timely judgment and response measures when the self-generating power system meets faults.

关 键 词:自发电系统 电子调速器 取力器 

分 类 号:TM611.2[电气工程—电力系统及自动化]

 