检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:牛童 NIU Tong(Housing and Construction Law Enforcement Administration of Hexi Tianjin,Tianjin 300000,China)
机构地区:[1]天津市河西区住房和建设综合行政执法支队,天津300000
出 处:《低温建筑技术》2020年第9期123-126,共4页Low Temperature Architecture Technology
摘 要:文中以甘肃省平凉市庄浪县为例,通过对当地农村土坯房和砖房维护结构传热系数进行计算,对西北农村地区住房保温性能进行分析。参照《严寒和寒冷地区居住建筑节能设计标准》,结合当地实际情况,提出危房改造节能保温方案,并对各方案进行比较。This paper taking Zhuanglang County(Pingliang City,Gansu Province)for example,analysizes the insulation performance of housing in rural areas in northwestern China,based on the calculation of the heat transfer coefficient of the building envelop of adobe houses and brick houses..Referring to the“Standards for Energy-Saving Design of Residential Buildings in Severe Cold and Cold Regions”and combining with the actual local actual conditions,the paper put forward the heat-insulating schemes for the reconstruction of dangerous buildings,and compares the schemes.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.176