时速160km动力集中动车组集便器液位100%报警原因分析及处置对策  被引量:1

Analysis and Countermeasures for Alarm of Liquid Level 100%of Toilets in 160 km/h Concentrated Power EMU

在线阅读下载全文

作  者:王钟辉 许进 张雪 WANG Zhonghui;XU Jin;ZHANG Xue(Changchun Vehicle Section of China Railway Shenyang Bureau Group Co.,Ltd.,Changchun 130000)

机构地区:[1]中国铁路沈阳局集团公司长春车辆段,长春130000

出  处:《现代制造技术与装备》2020年第9期171-171,175,共2页Modern Manufacturing Technology and Equipment

摘  要:针对时速160km动力集中动车组在东北高寒地区的运营情况,对集便器系统在日常运行过程中发生的液位100%报警典型故障进行深入分析研究,进行热力学计算,制定解决措施,解决伴热系统存在的问题,保证了旅客乘车的舒适性。In view of the operation situation of 160 km/h concentrated power EMU in the cold region of northeast China,the typical faults of liquid level 100%alarm occurred in the daily operation process of the vacuum toilet system was deeply analyzed and studied,and thermodynamic calculation was carried out to formulate solutions to solve the problems existing in the heat tracing system,thus ensuring the passenger comfort.

关 键 词:动力集中动车组 真空集便器 伴热系统 分析对策 

分 类 号:U269[机械工程—车辆工程]

 