某百万机组低压轴封温度偏低分析及处理  

Analysis and Treatment of Low Temperature of Low Pressure Shaft Seal of One Million Unit

在线阅读下载全文

作  者:彭华坚 PENG Huajian(Guangdong YuedianJinghai Power Generation Co.,Ltd.,Jieyang 515223)

机构地区:[1]广东粤电靖海发电有限公司,揭阳515223

出  处:《现代制造技术与装备》2020年第9期172-173,共2页Modern Manufacturing Technology and Equipment

摘  要:某厂两台百万机组一直存在低压轴封温度偏低、低压轴封蒸汽带水问题,通过增设减温水小旁路、更换减温水调阀改造,但效果并不理想。最终从#7号低压加热器出水母管取用一路水源汇合于原减温水调节阀前,提高减温水初始温度,有效控制低压轴封温度为150~160℃,从根本上解决了低压轴封温度偏低的缺陷,提高了机组和设备安全性能。The low temperature of low pressure shaft seal and water entrainment in steam of low pressure shaft seal have always existed in two million units of a plant.The effect is not ideal by adding small bypass of desuperheating water and replacing desuperheating water regulating valve.Finally,a water source is taken from the outlet header of#7 low-pressure heater and converged in front of the original desuperheating water regulating valve to improve the initial temperature of desuperheating water and effectively control the temperature of low-pressure shaft seal of 150~160℃,which fundamentally solves the defect of lowpressure shaft seal temperature and improves the safety performance of the unit and equipment.

关 键 词:百万机组 低压轴封 轴封温度 低压加热器 

分 类 号:TM621[电气工程—电力系统及自动化]

 