检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:郎旭海 史尚冕 侍雪雷 常伟 顾群 张玉明 LANG Xu-hai;SHI Shang-mian;SHI Xue-lei;CHANG Wei;GU Qun;ZHANG Yu-ming(North West Electric Power Design Institute Co.,Ltd.of CPECC,Xi’an 710075,China)
机构地区:[1]中国电力工程顾问集团西北电力设计院有限公司,陕西西安710075
出 处:《电力勘测设计》2020年第10期1-7,30,共8页Electric Power Survey & Design
摘 要:±800 kV特高压换流站辅助控制楼主体结构高度较小,楼梯间突出屋面部分高度较大,地震作用下鞭梢效应明显。建立8种计算模型,对4种输入条件下模型的结构响应进行了探讨。研究表明:辅助控制楼结构计算主要控制指标为层间位移角。地震烈度为6度、加速度为0.05g、特征周期为0.45 s时,建议模型1,其性能指标可满足规范限值要求。地震烈度为7度、加速度为0.10g、特征周期为0.45 s时,建议模型2、模型3和模型5,结构响应可满足规范限值要求。地震烈度为7度,加速度为0.10g、特征周期为0.75 s及地震烈度为7度、加速度为0.15g、特征周期为0.45 s时,建议模型4和模型6,计算结果可满足规范限值要求;地震烈度为7度、加速度为0.15g、特征周期为0.75 s及地震烈度为8度、加速度为0.20g时,建议采用框架剪力墙结构。The height of the main structure of auxiliary control building of±800kV UHV converter station is small,and the height of partial roofing part is large.Whipping effect under earthquake is obvious.The 8 structural calculation models have been established to analyze the structural response of models under 4 input conditions.The research shows the main control index of the auxiliary control building structure calculation is interlayer displacement angle.When the seismic intensity is 6 degree,the acceleration is 0.05g,and the characteristic period is 0.45 s,the model1 is advised.When the seismic intensity is 7 degree,the acceleration is 0.10g,and the characteristic period is 0.45 s,the performance indicators of model 2、model 3 and model 5 can meet the specification limit requirements.When the seismic intensity is 7 degree,the acceleration is 0.10g,the characteristic period is 0.75 s and the seismic intensity is 7 degree,the acceleration is 0.15g,the characteristic period is 0.45s,model4 and model6 are advised.When the seismic intensity is 7 degree,the acceleration is 0.15g,the characteristic period is 0.75 s and the seismic intensity is 8 degree,the acceleration is 0.2g,the characteristic period is 0.45 s,the model 8 which is frame shear wall structure is advised.
关 键 词:辅助控制楼 地震烈度 层间位移角 框架结构 框架—剪力墙结构
分 类 号:TM72[电气工程—电力系统及自动化]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.249