循环冷却水进水温度对凝汽器压力影响的定量分析  被引量:2

Quantitative Analysis on the Condenser Pressure Affectedby Inlet Temperature of Circulating Cooling Water

在线阅读下载全文

作  者:杨勤 杨希刚 马晓峰 杨文正 YANG Qin;YANG Xi-gang;MA Xiao-feng;YANG Wen-zheng(China Energy Investment Group Co.,Ltd.,Beijing 100034,China;Guodian Nanjing Electric Test Research Co.,Ltd.,Nanjing 210046,China)

机构地区:[1]国家能源投资集团有限责任公司,北京100034 [2]国电南京电力试验研究有限公司,南京210046

出  处:《汽轮机技术》2020年第5期393-395,共3页Turbine Technology

摘  要:在深入分析循环冷却水进水温度与凝汽器压力之间关系的基础上,提出了定量分析计算的方法。通过实例计算分析得出结论,在循环冷却水进水温度波动范围较小时,采用简化算法完全可以满足工程应用,而当循环冷却水进水温度波动范围较大时,应考虑凝汽器热负荷变化对凝汽器压力的影响,此时宜采用迭代算法。Based on the analysis of the relationship between circulating cooling water and condenser pressure,a method of quantitative calculation is presented.Trough computation and analysis by examples we can draw a conclusion,when the fluctuation range of inlet temperature of circulating cooling water is small,the simplified algorithm can fully meet the engineering application.When the fluctuation range of inlet temperature of circulating cooling water is wide,the influence of the condenser heat load changed should be considered.At this time,iterative calculation should be adopted.

关 键 词:进水温度 凝汽器压力 定量分析 迭代算法 

分 类 号:TK212.2[动力工程及工程热物理—动力机械及工程]

 