检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:赵美红 王新宇 姜岩秀 杨硕[1] 李文昊[1] ZHAO Mei-hong;WANG Xin-yu;JIANG Yan-xiu;YANG Shuo;LI Wen-hao(Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China;University of Chinese Academy of Sciences, Beijing 100049, China)
机构地区:[1]中国科学院长春光学精密机械与物理研究所,吉林长春130033 [2]中国科学院大学,北京100049
出 处:《光学精密工程》2020年第10期2103-2111,共9页Optics and Precision Engineering
基 金:科技部重点研发计划资助项目(No.2018YFF01011000);吉林省科技发展计划资助项目(No.20190303019SF);吉林省科技发展计划资助项目(No.20190103157JH)。
摘 要:为了在系统结构简单的前提下实现凸面光栅成像光谱仪的大相对孔径、高分辨率成像、轻小型化以及系统的易加工装调,优化设计了一种基于变间距凸面光栅的消像差凸面光栅成像光谱系统,该系统为双光学元件全反射式同心结构,克服了已有消像差结构的复杂性与应用局限性。提出了基于光栅的像差理论进行消像差的设计方法,构建了系统的几何像差理论模型,并结合罗兰圆条件分析了系统在子午与弧矢方向上的聚焦条件,建立了凸面光栅刻线间距与系统像散关系的数学模型;通过全局化的优化算法实现了对凸面光栅成像光谱仪的消像散设计。设计结果表明该消像散的凸面光栅成像光谱系统在300~800 nm实现了相对孔径为F/2.7时极限光谱分辨力优于1.9 nm的高像质成像,可实现约201个高光谱通道,而且系统在全波段内的光学传递函数值优于0.7,对轻小型、高光谱的消像差凸面光栅成像光谱仪的研究具有重要意义。An imaging spectrometer with a varied line-space convex grating was designed and optimized in this study to realize a large relative aperture,high-resolution imaging,and light miniaturization,thus ensuring easy processing,assembly,and adjustment of the optical system based on a simple system structure.With a double-element system in a reflection concentric structure,the complexity and application limitations of the existing aberration-correction configurations were overcome.An aberration-correction design method was proposed based on the aberration theory of gratings,and a theoretical model of the geometric aberration of the system was briefly derived.The focal conditions of the system in both the meridional and sagittal directions were then analyzed in combination with the Rowland circles of the concentric configuration.This analysis established a mathematical model of the relationship between the astigmatism and line spacing of the convex grating.Finally,an anastigmatic design of the imaging spectrometer with a convex grating was realized using a global optimization algorithm.Design results show that the system can achieve high-quality imaging in the spectral range of 300~800 nm with a large relative aperture of F/2.7 and a resolution of 1.9 nm.In addition,approximately 201 hyperspectral channels are covered.The modulation transfer function for the whole spectral band is greater than 0.7,which meets the design requirements of the system.This study contributes significantly to the research of hyperspectral imaging spectrometers with aberration-correction convex gratings in terms of light weight and compactification.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.33