IGCC电站空分预冷纯化系统技改节能优化探讨  被引量:1

Discussion on Energy Saving Optimization of Air Separation Precooling and Purification System in IGCC Power Station

在线阅读下载全文

作  者:梁小龙 王绍博 陈浩 赵可昕 LIANG Xiaolong;WANG Shaobo;CHEN Hao;ZHAO Kexin(Huaneng (Tianjin) IGCC Co. , Ltd. , Tianjin 300452, China)

机构地区:[1]华能(天津)煤气化发电有限公司运行部,天津滨海新区300452

出  处:《低温与特气》2020年第5期19-23,共5页Low Temperature and Specialty Gases

摘  要:根据华能IGCC电站的空分系统在节能降耗中遇到的问题对预冷系统中的冷水机组进行了技改,从而优化了运行方式。纯化系统的分子筛经过更新换代,吸附时间由原来4 h延长到6 h,节省了蒸汽的同时增强了空分运行的稳定性。The water chiller in the precooling system has been technically modified through the problems encountered in the air separation system of Huaneng IGCC power station in energy saving and consumption reduction,so as to optimize the operation mode.The molecular sieve of the purification system has been updated,and the adsorption time has been extended from the original four hours to six hours,saving steam and enhancing the stability of air separation operation.

关 键 词:IGCC电站 空分 冷水机组 分子筛 节能 