检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:任小朋[1] 高涌涛[2,3] REN Xiaopeng;GAO Yongtao(Sichuan College of Architectural Technology,Deyang 618000,China;Environment&Civil Engineering Department,Chengdu University of Technology,Chengdu 610059,China;State Key Laboratory of Geohazard Prevention and Geoenvironment Protection,Chengdu 610059,China)
机构地区:[1]四川建筑职业技术学院,德阳618000 [2]成都理工大学环境与土木工程学院,成都610059 [3]地质灾害防治与地质环境保护国家重点实验室,成都610059
出 处:《建筑结构》2020年第20期103-108,30,共7页Building Structure
基 金:国家科技支撑计划课题(2015BAK09B01);国家创新研究群体科学基金(41521002);地质灾害防治与地质环境保护国家重点实验室开放基金(SKLGP2019K019)。
摘 要:采用薄钢板剪力墙加固既有钢筋混凝土框架结构是一种简便有效的结构修复方法。为研究采用薄钢板剪力墙加固的带填充墙钢筋混凝土框架结构的抗震性能,对5个缩尺比为1∶3不同形式的两层单跨钢筋混凝土模型进行了水平荷载作用下的低周反复试验,分析了各模型的滞回性能、延性及耗能能力。结果表明,在水平荷载作用下薄钢板剪力墙加固的带有填充墙钢筋混凝土框架结构的水平承载力、耗能能力及延性均得到了明显的提升;与纯框架结构相比,有完整填充墙的框架结构的水平承载力、耗能能力和延性均有所提升,但带洞口填充墙的框架结构的延性并未提高;采用薄钢板剪力墙加固后的带填充墙钢筋混凝土框架结构的承载力和耗能能力均有提高,但延性均有降低,其原因是薄钢板平面内拉力场的作用引起钢筋混凝土框架柱内的剪力明显增加所致。It is a simple and effective method to use thin steel plate shear wall to reinforce existing reinforced concrete frame structure. In order to study the seismic performance of reinforced concrete frame structures with infill walls reinforced with thin steel plate shear walls, five two-story, single-span reinforced concrete models with a scale ratio of 1∶3 were performed under horizontal loads through low cycle trial and error. The hysteretic performance, ductility and energy dissipation capacity of each model were analyzed. The results show that the horizontal bearing capacity, energy dissipation capacity and ductility of reinforced concrete frame structures with thin steel plate shear walls have been significantly improved under horizontal loads. Compared with the pure frame structure, the horizontal bearing capacity, energy dissipation capacity and ductility of the frame structure with complete infilled wall have been improved, but the ductility of the frame with portal infilled wall has not been improved. The bearing capacity and energy dissipation capacity of reinforced concrete frame structure with the infill wall reinforced by the thin steel plate shear wall have been improved, but the ductility has been reduced. The reason is that the shear force in the reinforced concrete frame column is significantly increased due to the action of the tensile field in the plane of the thin steel plate.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.137.142.253