摘 要:配电站房作为配网系统的负荷中心,其关键设备的温度关系着供电是否正常运行。由于供电设备数量众多,大多采用无人值守方式,因此无法对其进行实时监测。为此,文章设计了一种基于低功耗广域网技术的配电室设备温度在线监测系统,对全站的重要供电设备进行温度、温升监测和管理,实现对配电站房的进出线母排、开关刀闸、开关柜等设备的在线温度监测、越限预警功能。As the load center of the distribution network system,the temperature of the key equipment of the power distribution room is related to the normal operation of the power supply.Due to the large number of power supply equipment,most of them are unattended,so they cannot be monitored in real time.Therefore,an on-line temperature monitoring system for distribution room equipment based on low-power WAN technology was designed,which could monitor and manage the temperature and temperature rise of the important power supply equipment in the whole station.