摘  要:介绍了电网无功消纳的方法及发电机进相运行的意义和特点,分析了发电机进相运行对发电机及厂用电系统的影响,计算与分析了#3发电机进相运行限制条件,提出了保证#3发电机安全进相运行的有关措施。The method of grid reactive power dissipation and the significance and characteristics of the generator in leading phase operation was introduced,and the influence of the generator in leading phase operation on the generator and the auxiliary power system was analyzed.the limiting conditions of#3 Generator in leading phase operation were calculated and analyzed,and relevant measures to ensure safe in leading phase operation of#3 generator were put forward.