检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:南东亮 王维庆[1] 任祖怡[3] 王开科 李兴建[3] 夏尚学[3] NAN Dongliang;WANG Weiqing;REN Zuyi;WANG Kaike;LI Xingjian;XIA Shangxue(Research Center of Renewable Energy Power Generation and Grid Control Engineering,Ministry of Education,Xinjiang University,Urumqi 830047,China;Electric Power Research Institute of State Grid Xinjiang Electric Power Co.,Ltd.,Urumqi 830011,China;NR Electric Co.,Ltd.,Nanjing 211102,China)
机构地区:[1]可再生能源发电与并网技术教育部工程研究中心,新疆大学,新疆维吾尔自治区乌鲁木齐市830047 [2]国网新疆电力有限公司电力科学研究院,新疆维吾尔自治区乌鲁木齐市830011 [3]南京南瑞继保电气有限公司,江苏省南京市211102
出 处:《电力系统自动化》2020年第21期165-171,共7页Automation of Electric Power Systems
基 金:国家自然科学基金资助项目(51667020);新疆维吾尔自治区高校科研计划自然科学资助项目(XJEDU2017I002)。
摘 要:目前区域电网安全稳定控制系统主要依赖出厂前的静态测试或实时数字仿真系统等仿真测试,现场联合调试和安全稳定控制策略动态验证不够完善,设备安装、调试检验、参数设置过程中可能存在的隐患难以完全排除,因此亟须建立有效的现场测试方法,确保安全稳定控制系统的可信可用。文中提出基于电力调度数据网、电力无线虚拟专网、全球定位系统构建大规模远程测试体系。以BPA和PSASP软件等中国电力调度部门常用仿真软件的仿真结果为输入信号源,各站测试终端经通信网络相连共同组成分布式远程测试平台进行安全稳定控制系统动态整组仿真测试。同时,对测试平台的组网架构、通信方式、控制方法和测试终端设计进行了详细介绍,并以中国新疆和田地区安全稳定控制系统为实例开展现场试点应用,实现了大规模安全稳定控制系统的可信测试。At present,the security and stability control system of a regional power grid mainly depends on the static test before delivery or simulation test in real time digital simulation system.The on-site joint test and dynamic verification of the security and stability control strategy are not perfect enough,it is difficult to completely eliminate hidden risks that may exist in the processes of equipment installation,test and parameter setting.So,it is urgent to establish an effective on-site test method to ensure the reliability and efficiency of the security and stability control system.In this paper,a large-scale remote test system is proposed based on power dispatching data networks,power wireless virtual networks and the global positioning system.The simulation results of the commonly used simulation softwares of power dispatching department in China,such as BPA and PSASP,are used as the input signal sources,the test terminals of each station are connected by communication network to form a distributed remote test platform for dynamic system-level simulation test of security and stability control systems.Meanwhile,the details of the network structure,communication mode,control method and the design of test terminals for the test platform are presented,taking the security and stability control system in Hetian,Xinjiang,China as an example,the on-site application is carried out,and the reliability test of the large-scale security and stability control system is realized.
关 键 词:安全稳定控制 动态整组仿真测试 可信测试 远程测试
分 类 号:TM73[电气工程—电力系统及自动化]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.77