作  者:张兴群[1] 邵致远 黎亚洲 徐洪涛[3] ZHANG Xing-qun;SHAO Zhi-yuan;LI Ya-zhou;XU Hong-tao(School of Energy and Power Engineering,Xi'an Jiaotong University,Xi'an,China,Post Code:710049;Shanghai Yanjing Combustion Testing Co.Ltd.,Shanghai,China,Post Code:201821;School of Energy and Power Engineering,University of Shanghai for Science and Technology,Shanghai,China,Post Code:200093)

机构地区:[1]西安交通大学能源与动力工程学院,陕西西安710049 [2]上海焱晶燃烧设备检测有限公司,上海201821 [3]上海理工大学能源与动力工程学院,上海200093

出  处:《热能动力工程》2020年第10期117-123,共7页Journal of Engineering for Thermal Energy and Power

基  金:国家重点研发计划(2018YFF0216000)。

摘  要:为研究过饱和工质节流压降对旋风分离器效率的影响,以水和空气为工质,搭建了旋风分离器效率测试实验系统,使用冷干机和空气调节系统来实现工质进口条件的控制,同时独立使用稳压罐保证雾化效果,系统地测试了不同进口条件和环境条件下旋风分离器效率。实验结果表明:通过对过饱和工质节流可以有效提升旋风分离器的分离效率,适用于常温或较高温度两相工质的分离,实验工况下,节流压降提升35.8 kPa时,分离效率提升可达1.8%;节流后工质温度的回升会明显降低气液旋风分离器的分离效果,因此需对节流后旋风分离器进行部分或完全隔热处理。In order to study the effect of the throttling pressure drop of the supersaturated working fluid on the efficiency of the cyclone separator,a cyclone separator efficiency test experiment system using water and air as the working fluid is set up in this paper.The inlet condition of working fluid is controlled by lyophilizer and air conditioning system,the tank regulator is used independently to ensure the atomization effect,and the efficiency of cyclone separator under different inlet conditions and environment conditions is systematically tested.The experiment results show that throttling the supersaturated working fluid can effectively improve the separation efficiency of cyclone separator,which is suitable for the separation of two-phase working fluid at normal temperature or higher temperature.In the experiment conditions,separation efficiency can be increased up to 1.8%with the throttling pressure drop being increased by 35.8 kPa.The rise of working fluid temperature after throttling will significantly reduce the separation effect of gas-liquid cyclone separator,so it is necessary to partially or completely insulate the cyclone separator after throttling.

关 键 词:节流 旋风分离器 分离效率 过饱和 

分 类 号:TK221[动力工程及工程热物理—动力机械及工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象