SF6电气设备新气充装质量检测控制措施  

Quality Inspection and Control Measures of SF6 Electrical Equipment Fresh Gas Filling

在线阅读下载全文

作  者:王永奇 陈宏刚 张正渊 曹碧波 马玲 WANG Yongqi;CHEN Honggang;ZHANG Zhengyuan;CAO Bibo;MA Ling(State Gird Gansu Electric Power Research Institute,Lanzhou 730050,China)

机构地区:[1]国网甘肃省电力公司电力科学研究院,甘肃兰州730000

出  处:《电工技术》2020年第19期129-130,136,共3页Electric Engineering

摘  要:介绍SF 6新气入网质量验收、检测方法,分析SF 6气体各检测手段的优缺点及影响试验结果的因素,提出了特高压电气设备SF 6新气质量检测过程中质量控制措施,给出SF 6电气设备在充装、验收、运行阶段各环节中把控危险因素的应对策措施,加强SF 6气体质量监督,确保特高压电气设备的安全、稳定运行。The quality acceptance and test methods of SF 6 fresh gas entering the network were introduced.The advantages and disadvantages of each test method of SF 6 gas and the factors influencing the test results were analyzed.The quality control measures in the process of testing the quality of SF 6 new gas for UHV electric equipment were proposed.The countermeasures for controlling the dangerous factors in the stages of charging,acceptance and operation of SF6 electric equipment were put forward,so as to strengthen the quality supervision of SF6 gas and ensure the safe and stable operation of UHV electrical equipment.