考虑后效性的柔性直流输电黑启动方案评估方法  被引量:8

Evaluation method of black-start scheme with VSC-HVDC considering aftereffects

在线阅读下载全文

作  者:刘旭斐 吴琛 张丹 黄伟 李鹏飞[2] LIU Xufei;WU Chen;ZHANG Dan;HUANG Wei;LI Pengfei(Yunnan Electric Power Dispatching and Control Center,Yunnan Power Grid Co.,Ltd.,Kunming 650011,China;School of Electrical and Electronic Engineering,North China Electric Power University,Baoding 071003,China)

机构地区:[1]云南电网有限责任公司云南电力调度控制中心,云南昆明650011 [2]华北电力大学电气与电子工程学院,河北保定071003

出  处:《电力科学与技术学报》2020年第6期110-116,共7页Journal of Electric Power Science And Technology

基  金:云南省电力公司科技项目(yndw(2016)000303DD00085)。

摘  要:柔性直流输电黑启动能很好地维持换流母线的电压稳定,并有效抑制可能出现的过电压问题,在此背景下,提出一种考虑后效性的柔性直流输电黑启动方案评估方法。首先,介绍柔性直流输电的运行特性;其次,综合考虑表征方案优劣的初期恢复评价指标和后效性评价指标,构建全面反映方案优劣的综合评价体系;然后,分别采用序关系分析法和改进CRITIC法确定主客观权重,在此基础上利用基于博弈论的组合赋权法求得各待评价指标的组合权重,并采用逼近理想解排序法对满足各类约束条件的柔性直流输电黑启动方案进行综合评价以确定其优劣程度。最后,以鲁西背靠背柔性直流通道对云南电网大停电后的供电恢复为研究背景,验证所提评估方法的有效性。The black start scheme for VSC-HVDC can maintain the voltage stability of the converter bus and effectively suppress the possible overvoltage problems.Under this background,an evaluation method is proposed for the black start scheme of VSC-HVDC considering aftereffects.Firstly,the operation characteristics of VSC-HVDC are introduced;Secondly,the initial recovery evaluation index and aftereffects evaluation index are comprehensively combined to characterize the pros and cons of the scheme.A comprehensive evaluation system is then established to fully reflect the pros and cons of the scheme.Thirdly,the order relation analysis method and the improved CRITIC method are utilized to determine the subjective and objective weight respectively.The combination weighting method based on game theory is then employed to obtain the combination weight of each index to be evaluated.Furthermore,a comprehensive evaluation of the black start scheme of HVDC satisfying all kinds of constraints is analyzed to determine the advantages and disadvantages.Finally,the feasibility of proposed method is verified by the restoration of the power supply with Luxi back-to-back VSC-HVDC system after a blackout in Yunnan power grid.

关 键 词:柔性直流输电 黑启动 评估 序关系分析法 改进CRITIC法 逼近理想解排序法 

分 类 号:TM74[电气工程—电力系统及自动化]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象