Integration of geoelectric and hydrochemical approaches for delineation of groundwater potential zones in alluvial aquifer  被引量:1

在线阅读下载全文

作  者:Qaisar Mehmood Muhammad Arshad Muhammad Rizwan Shanawar Hamid Waqas Mehmood Muhammad Ansir Muneer Muhammad Irfan Lubna Anjum 

机构地区:[1]Department of Irrigation&Drainage,Faculty of Agricultural Engineering&Technology,University of Agriculture,Faisalabad,38040,Pakistan [2]Department of Agriculture(Field Wing)Government of Punjab,Pakistan [3]Key Laboratory of Remote Sensing and Geospatial Science,Northwest Institute of Eco Environment and Resources,Chinese Academy of Sciences,Lanzhou 730000,China [4]University of Chinese Academy of Sciences,Beijing 100049,China [5]Khawaja Farid University of Engineering and Information Technology,Pakistan [6]Adaptive Research Farms,Agriculture Department(Extension&Research Wing)Punjab,Pakistan [7]PMU,Agriculture Department,Government of Punjab,Pakistan

出  处:《Journal of Groundwater Science and Engineering》2020年第4期366-380,共15页地下水科学与工程(英文版)

摘  要:Geoelectric and hydrochemical approaches are employed to delineate the groundwater potential zones in District Okara,a part of Bari Doab,Punjab,Pakistan.Sixty-seven VES surveys are conducted with the Electrical Resistivity Meter.The resultant resistivity verses depth model for each site is estimated using computer-based software IX1D.Aquifer thickness maps and interpreted resistivity maps were generated from interpreted VES results.Dar-Zarrouk parameters,transverse resistance(TR),longitudinal conductance(SL)and anisotropy(λ)were also calculated from resistivity data to delineate the potential zones of aquifer.70%of SL value is≤3S,30%of SL value is>3S.According to SL and TR values,the whole area is divided into three potential zones,high,medium and low potential zones.The spatial distribution maps show that north,south and central parts of study area are marked as good potential aquifer zones.Longitudinal conductance values are further utilized to determine aquifer protective capacity of area.The whole area is characterized by moderate to good and up to some extent very good aquifer protective area on the basis of SL values.The groundwater samples from sixty-seven installed tube wells are collected for hydro-chemical analysis.The electrical conductivity values are determined.Correlation is then developed between the EC(μS/cm)of groundwater samples vs.interpreted aquifer resistivity showing R2 value 0.90.

关 键 词:AQUIFER Groundwater potential zone Longitudinal conductance VES 

分 类 号:P641[天文地球—地质矿产勘探]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象