检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:黄婷 陈婕 郭欢 张寒旭 王晓亮 李炎 黄明 荣祖元 HUANG Ting;CHEN Jie;GUO Huan;ZHANG Hanxu;WANG Xiaoliang;LI Yan;HUANG Ming;RONG Zuyuan(Sichuan Institute for Food and Drug Control(Sichuan Testing Center of Medical Devices),Chengdu 611731)
机构地区:[1]四川省食品药品检验检测院(四川省医疗器械检测中心),成都611731
出 处:《北京生物医学工程》2020年第6期594-600,共7页Beijing Biomedical Engineering
摘 要:目的通过实时无标记细胞分析法(real time cell analysis,RTCA)与MTT法的比较研究,探讨RTCA法用于医疗器械细胞毒性常规检测的可行性。方法首先,通过筛选细胞接种密度建立基于L929细胞的RTCA细胞毒性检测方法。然后,使用不同浓度的DMSO稀释液、标准对照材料浸提液、56批真实世界的医疗器械产品,从简单到复杂分别比较RTCA法与MTT法用于细胞毒性检测结果的一致性,并且汇总多次试验的阴性对照和阳性对照结果,比较两种方法的可重复性。结果RTCA法检测不同浓度的DMSO稀释液没有剂量效应关系,检测标准对照材料浸提液与MTT法结果完全一致并高度相关(R=0.9898),检测56批医疗器械产品与MTT法结果一致率为80.4%,仅中度相关(R=0.6183)。RTCA法的可重复性不比MTT法好。结论RTCA法能有效检测医疗器械细胞毒性,但是部分产品可能因溶出物干扰检测结果而不适用。RTCA法作为一种新型的医疗器械细胞毒性检测方法的适用性还需要进一步研究。Objective A comparative study of real time cell analysis(RTCA)method with MTT method was conducted to demonstrate the feasibility of RTCA method on cytotoxicity tests of medical devices.Methods First,RTCA cytotoxicity test method based on L929 cell was established by screening cell inoculation density.Then,different concentrations of DMSO diluents,extracts of standard reference materials,56 batches of medical device products in the real world were used,from simple to complex,to compare for the consistency of RTCA and MTT methods in cytotoxicity test.The results of negative and positive controls from multiple experiments were collected to compare the repeatability of the two methods.Results The results of RTCA method showed no dose-effect relationship in the test of DMSO diluents.In the test of standard control material extracts,the results of RTCA method were completely consistent with MTT method and highly correlated(R=0.9898).In the test of 56 batches of medical device products,the consistency rate was 80.4%and only moderately correlated(R=0.6183).The repeatability of RTCA method was no better than that of MTT method.Conclusions RTCA method can effectively detect the cytotoxicity of medical devices,yet certain products are not applicable because their dissolves may interfere with the detection results.The applicability of RTCA as a new method to detect the cytotoxicity of medical devices needs further study.
关 键 词:实时无标记细胞分析法 MTT 医疗器械 细胞毒性
分 类 号:R318[医药卫生—生物医学工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.185