作 者:方娟 庞瑞冬 马爱琴[3] 王府梅[1,4] FANG Juan;PANG Ruidong;MA Aiqin;WANG Fumei(College of Textiles,Donghua University,Shanghai 201620,China;Inner Mongolia Erdos Resources Co.,Ltd,Erdos,Inner Mongolia 017000,China;Xinjiang Tacheng Region Fiber Inspection Institute,Wusu,Xinjiang 834700,China;Key Laboratory of Textile Science&Technology,Ministry of Education,Donghua University,Shanghai 201620,China)
机构地区:[1]东华大学纺织学院,上海201620 [2]内蒙古鄂尔多斯资源股份有限公司,内蒙古鄂尔多斯017000 [3]新疆塔城地区纤维检验所,新疆乌苏834700 [4]东华大学纺织面料技术教育部重点实验室,上海201620
出 处:《毛纺科技》2020年第12期67-72,共6页Wool Textile Journal
基 金:国家自然科学基金项目(51673036)。
摘 要:针对羊绒长度缺少标准的仪器化测量问题,研制出一台测量羊绒长度的新仪器—双须光电法羊绒测长仪1.0版,通过该仪器测量羊绒纤维长度并与GB 18267—2013《山羊绒》方法进行对比。结果表明:二者根数频率分布规律整体一致,一致性较高。通过对根数加权平均长度、短绒率、长度频率分布等指标的差异率分析,找出了部分样品测试结果偏倚较大的原因:主要有双须法目光判色不准引起的误差、被新仪器忽略的长度5~7mm短绒误差,及试样本身的差异所引起的误差。In response to the lack of standard instrumental measurement of cashmere length,the team independently developed a new instrument for measuring the length of cashmere-the double whisker photoelectric method cashmere length gauge version 1.0.The instrument was taken to test cashmere length,which was compared with the experimental data obtained by the center′s manual row test method specified in GB 18267—2013“Cashmere”.The results show that the frequency distribution of the fibers tested by the double whisker method is consistent with that of the hand row method.The consistency of the two test methods is relatively high.The feasibility of the double whisker method for measuring cashmere length is very high,hence this method has advantages of simple,fast and stable and so on.Meanwhile,by analyzing the difference ratios of the weighted average length,fluff rate,and length-frequency distribution of the fibers,the reasons for the bias in the test results of some samples are found:the mainly reasons are the error caused by the inaccurate color discrimination during the double whisker test,the error caused by a neglect to the short 5-7mm short pile by the 1.0 version,and the sample difference between the two measurement methods.The research provides the direction for the next improvement of the double whisker photoelectric cashmere length meter version 1.0.
分 类 号:TS131.8[轻工技术与工程—纺织材料与纺织品设计]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.222