测点布置对现浇非悬挑梁底纵向受力钢筋保护层厚度检测结果的影响  被引量:5

Influence of measuring point arrangement on the structural entity testing results of the thickness of protective layer of longitudinal stressed reinforcement at the bottom of non cantilever beam of cast-in-place structure

在线阅读下载全文

作  者:廖日熙 LIAO Rixi

机构地区:[1]福建省建研工程检测有限公司福建省绿色建筑技术重点实验室,福建福州350002

出  处:《福建建设科技》2020年第6期23-26,共4页Fujian Construction Science & Technology

摘  要:钢筋保护层厚度对结构的安全性、耐久性有很重要的影响,《混凝土结构工程施工质量验收规范》(GB 50204-2015)中对其检测作了详细规定,其中规定了对每根钢筋应选择有代表性的不同部位测量3点取平均值,但未明确规定如何选择该3个测点。文章结合工程实例,分析了结构实体构件中不同测点处的钢筋保护层厚度检测值的变化,并给出若干建议。The thickness of protective layer of reinforcement has a very important impact on the safety and durability of structures.The“Code for quality acceptance of concrete structure construction”(GB 50204-2015)has made detailed provisions,which stipulates that three representative different parts of each steel bar should be selected to measure the average value of three points,but it is not clear how to select the three measuring points.Combined with the engineering example,this paper analyzes the difference of the detection value of the reinforcement cover thickness at different measuring points in the structural entity component,and gives some suggestions.

关 键 词:钢筋保护层厚度 结构实体检测 

分 类 号:TU7[建筑科学—建筑技术科学]

 