作 者:顾栋炼 张银安[2] 刘华斌[2] 马友才[2] 曹晓庆[2] 吕中一 解琳琳 许镇 徐永嘉 郑哲 杨参天 陆新征[1] GU Dong-lian;ZHANG Yin-an;LIU Hua-bin;MA You-cai;CAO Xiao-qing;LU Zhong-yi;XIE Lin-lin;XU Zhen;XU Yong-jia;ZHENG Zhe;YANG Can-tian;LU Xin-zheng(Key Laboratory of Civil Engineering Safety and Durability of China Education Ministry,Department of Civil Engineering,Tsinghua University,Beijing 100084,China;Central-South Architectural Design Institute Co.Ltd.,Wuhan 430071,China;School of Civil and Transportation Engineering,Beijing University of Civil Engineering and Architecture,Beijing 100044,China;School of Civil and Resource Engineering,University of Science and Technology Beijing,Beijing 100083,China)
机构地区:[1]清华大学土木工程系,土木工程安全与耐久教育部重点试验室,北京100084 [2]中南建筑设计院股份有限公司,武汉430071 [3]北京建筑大学土木与交通工程学院,北京100044 [4]北京科技大学土木与资源工程学院,北京100083
出 处:《工程力学》2020年第12期243-249,共7页Engineering Mechanics
基 金:国家自然科学基金项目(U1709212);腾讯基金会科学探索奖项目。
摘 要:2019年末爆发的新型冠状病毒肺炎疫情对现有医疗系统造成了巨大压力,各地开始建设新型冠状病毒肺炎的集中治疗临时医院。临时医院排风口排出的气体可能对临时医院新风口或者周围环境造成污染。由于临时医院的设计和建造周期只有6 d^10 d,因此排风环境影响分析一般需要在几小时内完成。基于上述背景,该研究提出了一个临时医院排风环境影响的快速模拟方法。该方法以开源流体力学计算软件FDS为基础,实现了临时医院建筑的快速建模、基于云计算平台的分布式计算、以及有害空气流动的监测和可视化,为临时医院设计阶段的快速分析提供了专门工具。并以武汉雷神山医院为案例,说明了该方法在此次肺炎疫情防疫工作中的应用价值。The outbreak of the novel coronavirus pneumonia at the end of 2019 imposed severe pressure on the medical system of China.Several Chinese cities began to build temporary hospitals for the centralized treatment of the pneumonia patients.Because the design and construction of the temporary hospital must be completed in 6 to 10 days,only a few hours are allowed for the analysis of the impact of exhausted air on the surrounding environment.To overcome this difficulty,a high-efficiency simulation method for analyzing the impact of exhausted air is proposed in this study.Based on the open-source computational-fluid-dynamics(CFD)software FDS,the proposed method realizes the fast modeling of temporary hospitals,the cloud computing-based CFD computation,and the monitoring and visualization of harmful air.The proposed method provides an efficient tool for the rapid analysis in the design stage of new-built temporary hospitals.A case study of Wuhan Leishenshan Hospital was conducted to demonstrate the application value of the proposed method in the epidemic prevention of the pneumonia.
关 键 词:新型冠状病毒肺炎 污染扩散模拟 FDS 快速建模 云计算
分 类 号:X502[环境科学与工程—环境工程] TB126[理学—工程力学]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.222