2#14000 m^3/h制氧机组氩馏分无法抽出原因分析  

Cause Analysis of Argon Fraction cannot be Extracted from No.2 14 000 m^3/h Oxygen Generating Unit

在线阅读下载全文

作  者:刘志茹 LIU Zhiru(Oxygen Plant of Anyang Iron and Steel Group Co.,Ltd.,Anyang,Henan 455004,China)

机构地区:[1]安阳钢铁公司制氧厂,河南安阳455004

出  处:《冶金动力》2020年第12期34-36,共3页Metallurgical Power

摘  要:14000 m3/h制氧机组制氩系统发生馏分量无法抽取问题,先后三次投运了制氩系统,对三次投氩情况,进行了讨论分析,采取了一系列措施,氩系统工况恢复正常,并提出后期完善工作。The argon production system of the 14000 m3/h oxygen generating unit has been put into operation for three times but the argon fraction could not be extracted.The problem was discussed and a series of measures have been taken to recover the working condition of argon system.Improvement work in the later stage was also put forward.

关 键 词:氩系统 氩馏分 抽出 