检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:Waqas Ullah Casey Meizinger Zain Ali Ankur Panchal Rehan Saeed Donald C Haas Eduardo Rame
机构地区:[1]Department of Internal Medicine,Abington Jefferson Health,Abington,PA 19001,United States [2]Department of Internal Medicine,University of Pittsburgh,Pittsburgh,PA 15213,United States [3]Department of Cardiology,Abington Jefferson Health,Abington,PA 19001,United States [4]Department of Cardiology,Thomas Jefferson University,Abington,PA 19001,United States
出 处:《World Journal of Cardiology》2020年第11期550-558,共9页世界心脏病学杂志(英文版)(电子版)
基 金:The authors have read the PRISMA 2009 Checklist,and the manuscript was prepared and revised according to the PRISMA 2009 Checklist.
摘 要:BACKGROUND Given current evidence,the effect of left ventricular assist device(LVAD)implantation on pulmonary function tests remains controversial.AIM To better understand the factors contributing to the changes seen on pulmonary function testing and the correlation with pulmonary hemodynamics after LVAD implantation.METHODS Electronic databases were queried to identify relevant articles.The summary effect size was estimated as a difference of overall means and standard deviation on a random-effects model.RESULTS A total of four studies comprising 219 patients were included.The overall mean forced expiratory volume in one second(FEV1),forced vital capacity(FVC)and diffusion lung capacity of carbon monoxide(DLCO)after LVAD implantation were significantly lower by 0.23 L(95%CI:0.11-0.34,P=00002),0.18 L(95%CI:0.03-0.34,P=0.02),and 3.16 mmol/min(95%CI:2.17-4.14,P<0.00001),respectively.The net post-LVAD mean value of the cardiac index was significantly higher by 0.49 L/min/m2(95%CI:0.31-0.66,P<0.00001)compared to pre-LVAD value.The pulmonary capillary wedge pressure and pulmonary vascular resistance were significantly reduced after LVAD implantation by 8.56 mmHg(95%CI:3.78-13.35,P=0.0004),and 0.83 Woods U(95%CI:0.11-1.55,P=0.02),respectively.There was no significant difference observed in the right atrial pressure after LVAD implantation(0.61 mmHg,95%CI:-2.00 to 3.32,P=0.65).Overall findings appear to be driven by studies using HeartMateII devices.CONCLUSION LVAD implantation might be associated with a significant reduction of the spirometric measures,including FEV1,FVC,and DLCO,and an overall improvement of pulmonary hemodynamics.
关 键 词:Pulmonary function tests Left ventricular assist device SPIROMETRY Ventricular assist device
分 类 号:R541.6[医药卫生—心血管疾病]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.7