检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:伍美芳 王春花[1] 熊杉杉 蒋明[1] 谭国林[1] WU Meifang;WANG Chunhua;XIONG Shanshan;JIANG Ming;TAN Guolin(Department of Otolaryngology Head and Neck Surgery,the Third Xiangya Hospital,Central South University,Changsha 410013,China)
机构地区:[1]中南大学湘雅三医院耳鼻咽喉头颈外科,湖南长沙410013
出 处:《中国耳鼻咽喉颅底外科杂志》2020年第6期641-644,共4页Chinese Journal of Otorhinolaryngology-skull Base Surgery
基 金:国家自然科学基金(81870708)。
摘 要:目的探讨应用神经反应遥测技术(NRT)在人工耳蜗植入术中监测,术后调机中的作用和经验体会。方法回顾性分析38例经历人工耳蜗植入的婴幼儿的临床资料,收集每例患者在术中、术后开机、调机应用NRT测试电诱发听神经复合动作电位(ECAP)的阈值数据,应用听觉整合量表(IT-MAIS)评估行为听觉言语功能。结果38例婴幼儿在术中植电极进入耳蜗后均实施NRT测试,每例测试5个电极,分别为1、6、11、16、22号电极,共测试了190个电极,其中163个电极(85.8%)引出了ECAP,其平均阈值为(163.8±21.2)CL。近端1号电极ECAP阈值显著高于远端22号电极(P<0.05)。从开机到开机后12个月,各电极ECAP阈值无显著变化。3岁以下患儿中,25例患儿在各次NRT测试时所有电极都能引出ECAP,而8例患儿存在1~5个电极不能引出ECAP,在开机12个月后,后者的IT-MAIS积分与前者比较差异无统计学意义(P>0.05)。结论人工耳蜗植入后NRT测试的ECAP阈值在近端电极显著高于远端电极,耳蜗内数个电极引不出ECAP不影响术后的听觉言语康复。Objective To explore the role and application experience of nerve response telemetry(NRT)in intraoperativve monitoring and postoperative management of cochlear implant.Methods Clinical data of 38 infants undergoing cochlear implant were analyzed retrospectively.The thresholds of electrically evoked auditory nerve compound action potential(ECAP)were measured by NRT during and after operation,and the rehabilitation of behavior hearing and language was evaluated by Infant-Toddler Meaningful Auditory Integration Scale(IT-MAIS).Results ECAP was evoked in 85.8%(163/190 electrodes)of the test electrodes by NRT during the procedure of cochlear implant,and the ECAP threshold of the proximal first electrode was significantly higher than that of the distal twenty-second electrode(P<0.05).There was no significant change in the ECAP thresholds of each electrode from switch-on of cochlear devices to 12 months after switch-on.Among infants younger than 3 years old,ECAP was evoked in all electrodes from each NRT test in 25 cases,absent in 1 to 5 electrodes in 8 cases.Twelve months after switch-on,the difference of IT-MAIS score between them was statistically insignificant(P>0.05).Conclusions The ECAP threshold of NRT after cochlear implant in the proximal electrode is significantly higher than that in the distal electrode.Absence of several electrodes in ECAP evoked by NRT does not affect the hearing and speech rehabilitation.
分 类 号:R764.93[医药卫生—耳鼻咽喉科]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.7