悬垂线夹金具力学性能试验工装优化  被引量:4

Tooling Optimization for Mechanical Property Test of Suspension Clamp Fittings

在线阅读下载全文

作  者:屈直 李志翔 焦宗寒 QU Zhi;LI Zhixiang;JIAO Zonghan(Yunnan Electric Power Technology Co.,Ltd.,Kunming 650217,China;Electric Power Research Institute,Yunnan Power Grid Co.,Ltd.,Kunming 650217,China)

机构地区:[1]云南电力技术有限责任公司,昆明650217 [2]云南电网有限责任公司电力科学研究院,昆明650217

出  处:《理化检验(物理分册)》2020年第11期1-6,11,共7页Physical Testing and Chemical Analysis(Part A:Physical Testing)

摘  要:挂具的柔性钢缆在受力时发生的变形较大,导致悬垂角保持在1/2线夹出口角(α)内比较困难。过大的导线悬垂角会导致线夹受到超过设计要求的弯矩挤压,从而发生破坏,导致试验结果不能真实地反映线夹的力学性能。通过分析和计算得出悬垂线夹力学性能试验过程中的受力特点,并对试验工装进行优化设计,然后将新型试验工装与柔性和刚性工装进行对比试验。结果表明:新型试验工装能将α/2角控制在标准规定范围内,解决了标准规定的试验方法中难以将α/2角控制在规定范围内导致试验结果失真的问题,从而提高悬垂线夹力学性能试验过程的规范性和试验结果的准确性。It is difficult to keep the suspension angle within 1/2 of the clamp outlet angle(α)due to the large deformation of the flexible steel cable of the hanger.The suspension angle of conductor was too large,the clamp been squeezed by the bending moment exceeding the design requirements,which led to the failure of the clamp,and the test results could not truly reflect the mechanical properties of the clamp.The loading characteristics of suspension clamp in the process of mechanical property test were obtained through analysis and calculation,and the experimental tooling was optimized,and then the new test tooling was compared with the flexible and rigid equipment.The results show that the new test tooling can control theα/2 angle within the standard range,which solved the problem that it was difficult to control theα/2 angle within the specified range in the standard test method,which led to the distortion of the test results.The standardization of mechanical property test process and the accuracy of the test results of the suspension clamp were improved.

关 键 词:悬垂线夹 力学性能试验 悬垂角 工装优化 

分 类 号:TB302.3[一般工业技术—材料科学与工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象