某燃机电厂高旁阀内漏故障分析及处理  被引量:1

在线阅读下载全文

作  者:吴静沛 朱伟雄[1] 

机构地区:[1]杭州华电半山发电有限公司,浙江杭州310015

出  处:《科技创新与应用》2021年第2期132-134,共3页Technology Innovation and Application

摘  要:针对高旁阀修后短期内频繁内漏的问题,分析总结故障原因,提出一种阀门改型的方法,采用防止密封面冲刷结构并带有保护套的阀芯结构,避免阀门密封面受到汽水冲刷,同时采用退让槽特殊设计的阀座,且保证阀座硬度高于阀芯硬度。改型后的阀门,在多次机组启停后检查均未出现内漏问题。In view of the frequent internal leakage of the high side valve in the short term after repair,the causes of the failure are analyzed and summarized,and a method of valve modification is put forward.The valve core structure with protective sleeve is adopted to prevent the valve sealing surface from being washed by steam and water.At the same time,the specially designed valve seat of the concession groove is adopted to ensure that the hardness of the valve seat is higher than that of the valve core.After the retrofit of the valve,there is no problem of internal leakage after many times of unit start-up and shutdown.

关 键 词:高旁阀 内漏 密封组件 防冲刷结构 

分 类 号:TM621.7[电气工程—电力系统及自动化]

 