离子淌度-飞行时间质谱测定减压蜡油芳香分及胶质中的碱性氮化物  被引量:2

CHARACTERIZATION OF BASIC NITROGEN COMPOUNDS IN AROMATIC AND RESIN FRACTIONS IN VACCUM GAS OILS BY ION MOBILITY-TIME-OF-FLIGHT MASS SPECTROMETRY

在线阅读下载全文

作  者:窦民娜 喻昊 刘为民 曹青 陈菲 余颖龙 张占全 王延飞 Dou Minna;Yu Hao;Liu Weimin;Cao Qing;Chen Fei;Yu Yinglong;Zhang Zhanquan;Wang Yanfei(PetroChina Petrochemical Research Institute,Beijing 102206;China University of Petroleum(Beijing);Quality Inspection Center,PetroChina Daqing Petrochemical Company)

机构地区:[1]中国石油石油化工研究院,北京102206 [2]中国石油大学(北京) [3]中国石油大庆石化分公司质量检验中心

出  处:《石油炼制与化工》2021年第1期103-110,共8页Petroleum Processing and Petrochemicals

基  金:中国石油天然气股份有限公司科学研究与技术开发项目(2020D-5006-86)。

摘  要:采用柱层析法将减压蜡油(VGO)分离为饱和分、芳香分和胶质,然后用电喷雾电离源(ESI)离子淌度-飞行时间质谱(IMS-TOF MS)对其芳香分与胶质中的碱性氮化物进行了表征,对不同来源的VGO中碱性氮化物的结构差异进行了分析。结果表明:对于不同来源的VGO样品,即使碱性氮化物不饱和程度接近,其芳环的连接方式也存在明显差异;而对于同一样品的芳香分和胶质,则存在碳数相近,但胶质中等效双键数稍低的现象。以核磁共振波谱仪异核单量子相干试验和加氢脱氮反应评价作为辅证,进一步推测了VGO中碱性氮化物的芳环侧链长度与其脱除难度之间的关联。将柱层析分离技术与ESI IMS-TOF MS联用,可以解决高蜡含量样品难以溶解的问题,并减弱强极性组分的离子化抑制作用,得到比直接进样更为全面的质谱信息。Vacuum gas oil(VGO)samples were separated into saturates,aromatics and resin by column chromatography,then the basic nitrides in aromatics and resin fractions were characterized by electrospray ionization source(ESI)ion mobility-time-of-flight mass spectrometry(IMS-TOF MS),and the structural differences of the basic nitrides in VGOs from different sources were analyzed.The results showed that for VGO samples from different sources,even if the unsaturated degree of basic nitride was close,there were obvious differences in the connection mode of aromatic ring;however,for the aromatic components and resin of the same sample,the carbon number was similar,and the number of equivalent double bonds in resin was slightly lower.Taking the heteronuclear single quantum coherence test of NMR spectrometer and the evaluation of hydrodenitrogenation reaction as the auxiliary evidence,the relationship between the side chain length of aromatic ring of basic nitride in VGO and its removal difficulty was further speculated.Combining column chromatography with ESI IMS-TOF MS can solve the problem that samples with high wax content are difficult to dissolve,and weaken the ionization inhibition of strong polar components,thus obtaining more comprehensive mass spectrum information than direct injection.

关 键 词:减压蜡油 氮化物 离子淌度 飞行时间质谱 柱层析 核磁共振波谱 

分 类 号:TE622.1[石油与天然气工程—油气加工工程] O657.63[理学—分析化学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象