引射汇流供热方式的经济性分析  被引量:2

Economical Analysis on the Application of Ejection Confluence in Heat-supplying

在线阅读下载全文

作  者:郑之民 ZHENG Zhimin(Datang Lubei Power Generation Co.,Ltd.,Binzhou 251909,China)

机构地区:[1]大唐鲁北发电有限责任公司,山东滨州251909

出  处:《山东电力技术》2020年第12期77-80,共4页Shandong Electric Power

摘  要:以某330 MW热电联产机组引射汇流供热改造为研究对象,分别基于等效热降法与热力试验法对机组210~320 MW负荷80 t/h供热下引射汇流与再热热段供热进行了计算对比,结果表明等效热降法计算误差在可控范围内,引射汇流供热装置利用冷段高品质蒸汽引射五抽低品质蒸汽实现了热能的按质利用,提高了机组供热经济性,在供热流量80 t/h机组负荷在230 MW以上时降低煤耗约2 g/kWh。Based on a 330 MW combined heat and power unit model,when the unit load is 210-320 MW and the extraction steam flow is 80 t/h,the energy saving effect of the ejection confluence and reheat steam extraction for heating are compared based on results obtained via the equivalent heat drop method and the thermal test method respectively.The results show that the calculation error of the equivalent heat drop method is within the controllable range.The jet confluence heating device uses high-quality cold reheat steam to jet low-quality five-stage extraction steam to realize the effective utilization of heat energy and improve the heating economy of the unit.When the unit load is more than 230 MW and the heating steam flow is 80 t/h,the coal consumption rate of power supply decreases by about 2 g/kWh.

关 键 词:引射汇流 等效热降 热力试验 经济性分析 

分 类 号:TM621[电气工程—电力系统及自动化]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象