作  者:朱海华[1] 陈智[6,7] 黄华玲[2] 陈亚丹[3] 赵洁[4] 饶春梅[5] 李懿[8,9] 陈宇博 林秧 ZHU Haihua;CHEN Zhi;HUANG Hualing;CHEN Yadan;ZHAO Jie;RAO Chunmei;LI Yi;CHEN Yubo;LIN Yang(Department of Nursing,The First Affiliated Hospital of Xiamen University,Xiamen Fujian 361002,China;Department of Neurosurgery,The First Affiliated Hospital of Xiamen University,Xiamen Fujian 361002,China;Department of Cardiovascular,The First Affiliated Hospital of Xiamen University,Xiamen Fujian 361002,China;Operating Room,The First Affiliated Hospital of Xiamen University,Xiamen Fujian 361002,China;Department of Otorhinolaryngology Head and Neck Surgery,The First Affiliated Hospital of Xiamen University,Xiamen Fujian 361002,China;Department of Medical,Xiamen Hospital of Traditional Chinese Medicine,Xiamen Fujian 361009,China;Orthopedics and Traumatology Department of Hexiang,Xiamen Hospital of Traditional Chinese Medicine,Xiamen Fujian 361009,China;Health Management Center,Jinjiang Hospital,Jinjiang Fujian 362200,China;First Department of Orthopaedics,Jinjiang Hospital,Jinjiang Fujian 362200,China;Department of Support,Xiamen Humanity Hospital,Xiamen Fujian 361009,China;Department of Nursing,Xiamen Medical College,Xiamen Fujian 361023,China)

机构地区:[1]厦门大学附属第一医院护理部,福建厦门361002 [2]厦门大学附属第一医院神经外科,福建厦门361002 [3]厦门大学附属第一医院心血管内科,福建厦门361002 [4]厦门大学附属第一医院手术室,福建厦门361002 [5]厦门大学附属第一医院耳鼻喉头颈外科,福建厦门361002 [6]厦门市中医院医务部,福建厦门361009 [7]厦门市中医院禾祥骨伤科,福建厦门361009 [8]晋江市医院健康管理中心,福建晋江362200 [9]晋江市医院骨一科,福建晋江362200 [10]厦门弘爱医院保障部,福建厦门361009 [11]厦门医学院护理学系,福建厦门361023

出  处:《中国医疗设备》2021年第1期23-26,35,共5页China Medical Devices

基  金:福建省医学创新课题(2017-CXB-21)。

摘  要:目的为克服YY0175-2005手术刀柄与刀片不通配、拆刀片时可能发生伤人等缺欠,防范手术刀锐器伤,研制了“折携式任向通配模块化手术刀柄”。方法通过机械性能试验及动物模拟手术试验方法在便捷性、安全性、择向性、舒握性、防滑性、捷拾性、调节性、便携性、人机性等方面与普通刀柄对照验证、评价。结果折携刀柄综合性能优于普通刀柄。结论双面便卸式配合体及多功能握柄构成的折携刀柄安全、便捷、抗损、通配及携储功效优异,适于巡回医疗、抢险救灾或野战外科应急卫勤保障。Objective To overcome the defects of YY0175-2005 scalpel handle such as the mismatching between the handle and the blade,and the possible injury when disassembling the scalpel blade,to prevent sharp instrument injury of the scalpel,“a folding portable-type modular scalpel handle with omnidirectional configuration”was developed.Methods Through the mechanical performance test and animal simulation operation test methods,the new scalpel handle was evaluated and compared with ordinary scalpel handle in terms of convenience,safety,orientation,ease of grip,skid resistance,facile of picking up,adjustability,portability,man-machine performance and other aspects.Results The comprehensive performance of the folding portable scalpel handle was superior to that of common scalpel handle.Conclusion The double-sided removable ligand and multi-function handle has excellent efficacies in safe,convenient,damage resistant,universal matching and carrying storage.It is suitable for itinerant medical treatment,rescue and relief or emergency medical support for field surgery.

关 键 词:手术刀柄 主动防护 人因失误 锐器伤 患者安全目标 

分 类 号:R197.39[医药卫生—卫生事业管理]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象