检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:张涛[1,2] 李进 薛明军 张灏[1,2] 李玉平 胡萌萌[1] Zhang Tao;Li Jin;Xue Mingjun;Zhang Hao;Li Yuping;Hu Mengmeng(Guodian Nanjing Automation Co.,Ltd.,Nanjing 210032,China;Nanjing Guodian Nanzi Grid Automation Co.,Ltd.,Nanjing 211153,China)
机构地区:[1]国电南京自动化股份有限公司,南京210032 [2]南京国电南自电网自动化有限公司,南京211153
出 处:《国外电子测量技术》2020年第11期102-106,共5页Foreign Electronic Measurement Technology
摘 要:光纤通道告警是微机保护最常见的故障,对于经常发生的瞬时告警瞬时复归、反复发生的情况,由于故障现象难以捕捉,给故障处理带来很大不便。针对典型电力系统应用场景,结合无线通信通道状态信息获取方式和长短报文结合、信息分层分类处理的技术,设计了通道状态在线感知装置,结果为该装置可实时监测通道质量、定位异常区段、记录异常报文。结果表明,该技术的运用实现了通道状态信息的在线感知及离线挖掘,有效解决了变电站纵联光纤通道无记录、故障区间定位难等问题,缩短了继电保护通道故障处理时间,大大提升了工作效率。Fibre channel alarms are the most common failures of microcomputer protection.For the frequently occurring instantaneous alarms that instantly reset and recur,it is difficult to capture the failure phenomenon,which brings great inconvenience to the troubleshooting.Aiming at typical power system application scenarios,this paper designs a channel status online sensing device based on the wireless communication channel status information acquisition method,long and short message combination,and information hierarchical classification processing technology.The result is that the device can monitor channel quality in real time and locate abnormalities,section and record abnormal messages.The results show that the application of this technology realizes the online perception of channel status information and offline mining,effectively solves the problems of no record in the longitudinal fiber channel of the substation,difficulty in locating the fault section,and shortens the relay protection channel the troubleshooting time greatly improves work efficiency.
关 键 词:在线感知 状态获取 继电保护 线路保护 故障记录 无线通信
分 类 号:TN2[电子电信—物理电子学]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.170