Ceramic-on-ceramic vs ceramic-on-polyethylene,a comparative study with 10-year follow-up  被引量:1

在线阅读下载全文

作  者:Justin van Loon Daniël Hoornenborg Harm M van der Vis Inger N Sierevelt Kim TM Opdam Gino MMJKerkhoffs Daniël Haverkamp 

机构地区:[1]Department of Orthopedic Surgery,Xpert Orthopedie Amsterdam/SCORE(Specialized Center of Orthopedic Research and Education),Amsterdam 1101EA,The Netherlands [2]Department of Orthopedic Surgery,Amsterdam University Medical Centres,location Academic Medical Center,Amsterdam 1105AZ,The Netherlands [3]Department of Orthopedic Surgery,Spaarne Gasthuis,Hoofddorp 2134TM,The Netherlands

出  处:《World Journal of Orthopedics》2021年第1期14-23,共10页世界骨科杂志(英文版)

摘  要:BACKGROUND In press-fit total hip arthroplasty(THA)ceramic-on-ceramic(CoC)bearings are a potential for overcoming the wear that is seen in ceramic-on-polyethylene(CoPE)bearings,and can lead to wear-induced osteolysis,resulting in loosening of the implant.However,CoC bearings show disadvantages as well,such as squeaking sounds and being more fragile,which can cause ceramic head or liner fracture.Because comparative long-term studies are limited,the objective of this study was to determine the long-term difference in wear,identify potential predictive factors for wear,investigate radiological findings such as osteolysis,and evaluate clinical functioning and complications between these bearings.AIM To determine 10-year differences in wear,predictive factors for wear,and investigate radiological findings and clinical functioning between CoC and CoPE.METHODS This observational prospective single-center cohort study with a 10-year followup includes a documented series of elective THAs.Primary outcome was wear measured by anteroposterior(AP)radiographs.Secondary outcomes were potential predictive factors for wear,complications during follow-up,Harris hip score(HHS),and radiological findings such as presence of radiolucency,osteolysis,atrophy,and hypertrophy around the cup.Due to the absence of wear in the CoC group,stratified analysis to identify risk factors for wear was only performed in the CoPE group by use of univariate linear regression analysis.HHS was expressed as a change from baseline and the association with bearing type was assessed by use of multivariate linear regression analysis,adjusted for potential confounders.RESULTS A total of 17 CoPE(63.0%)and 25 CoC(73.5%)cases were available for follow-up and showed a linear wear of respectively 0.130 mm/year(range 0.010;0.350)and 0.000 mm/year(range 0.000;0.005),which was significant(P<0.001)between both groups.Wear always occurred in the cranial direction.Cup inclination was the only predictive factor for polyethylene(PE)wear.No dislocations,ceramic head,or line

关 键 词:Total hip arthroplasty PRESS-FIT Bearing CERAMIC-ON-CERAMIC Ceramic-onpolyethylene Wear 

分 类 号:R318.08[医药卫生—生物医学工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象