检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:石活顺[1] 邵国丰[1] 赵顺英[2] 胡晓燕[2] SHI Huoshun;SHAO Guofeng;ZHAO Shunying;HU Xiaoyan(Department of Cardiothoracic Surgery,Ningbo Medical Treatment Centre of Lihuili Hospital,Ningbo 315041,China;Department of Cardiac Care Unit,Ningbo Medical Treatment Centre of Lihuili Hospital,Ningbo 315041,China)
机构地区:[1]宁波市医疗中心李惠利医院心胸外科,浙江宁波315041 [2]宁波市医疗中心李惠利医院心脏监护室,浙江宁波315041
出 处:《温州医科大学学报》2021年第1期62-65,共4页Journal of Wenzhou Medical University
基 金:浙江省基础公益研究计划项目(LGD20H020001);宁波市科技惠民项目(2017c5044)。
摘 要:目的:了解机械瓣膜置换术后患者华法林相关并发症的相关影响因素。方法:选取2012年1月至12月在宁波市医疗中心李惠利医院行机械瓣膜置换的患者为研究对象,通过电话随访结合门诊随访情况,记录患者一般情况、抗凝情况、凝血功能等指标。对于分类变量采用χ2检验,多因素分析采用logistic回归模型。结果:抗凝药物依从性及房颤在有、无抗凝并发症2组间差异有统计学意义(P<0.05),瓣膜置换类型、年龄、文化程度、脑梗史、烟酒史、其他长期药物史在2组间差异无统计学意义(P>0.05)。多因素logistic回归显示房颤及抗凝药物依从性与抗凝并发症显著相关,OR值分别为2.570、4.628。结论:抗凝药物依从性差及房颤是机械瓣膜术后发作抗凝并发症的独立危险因素。Objective:To investigate the influencing factors of warfarin-related complications in mechanical valve patients,so as to understand the factors that may influence patients'anticoagulation compliance.Methods:Patients who had mechanical valve replacement in Ningbo Medical Treatment Centre of Lihuili Hospital from January to December 2012 were enrolled in this investigation.The questionnaire,which included general information of patients,anticoagulant condition,coagulation function and other indicators,was completed by all subjects mainly via telephone visits and outpatient follow-up.Chi-square test was used for categorical variables,and logistic regression model for multivariate analysis.Results:There was statistical difference in anticoagulant compliance and atrial fibrillation(AF)between two groups of anticoagulation complications(P<0.05),while there’s no significant difference between the two groups in the type of valve replacement,patient’s age,education,history of cerebral infarction,history of tobacco and alcohol and other long-term drug history(P>0.05).Multivariate logistic regression showed that AF and anticoagulation compliance were significantly associated with anticoagulant complications,with OR values being 2.570 and 4.628 respectively.Conclusion:Poor compliance with administration of warfarin and atrial fibrillation are independent risk factors for anticoagulation complications after mechanical valve replacement.
关 键 词:机械瓣膜置换 华法林 抗凝并发症 抗凝药物依从性
分 类 号:R541[医药卫生—心血管疾病]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.28