检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:Diyana Jamaludin Samsuzana Abd Aziz Desa Ahmad Hawa Z.E.Jaafar
机构地区:[1]Department of Biological and Agricultural Engineering,Faculty of Engineering,Universiti Putra Malaysia,43400 UPM Serdang,Selangor,Malaysia [2]Department of Crop Science,Faculty of Agriculture,Universiti Putra Malaysia,43400 UPM Serdang,Selangor,Malaysia
出 处:《Information Processing in Agriculture》2015年第3期161-168,共8页农业信息处理(英文)
基 金:The authors gratefully acknowledge the financial support from the Ministry of Education Malaysia and Universiti Putra Malaysia with the UPM Research Grant Scheme(Project Code:GP-IPS/2013/9399814);The authors would also like to acknowledge Mrs.Nadirah Roslan who was involved in data collection process.
摘 要:Labisia pumila(Kacip fatimah)is a popular medicinal plant in Malaysia.The constituents of this plant have been reported to possess anticancer,antioxidant and anti-inflammatory properties.The growth and production of L.pumila is greatly influenced by the plant water status.Current techniques to measure plant water status are generally based on the plant soil moisture,which apparently did not indicate the real water content inside the plant.There are other techniques to measure directly on the plant such as based on leaf water potential(LWP)and relative water content(RWC).However,these techniques are destructive and time consuming.In this study,four levels of evapotranspiration replacement(ER)treatment which were 100%ER,75%ER,50%ER and 25%ER was applied to 30 polybags of L.pumila plants.The plant water status was measured using an impedance spectroscopy technique.A pair of electrocardiogram(ECG)electrode connected to an impedance analyzer board was used to measure the impedance value of the leaf samples noninvasively.Plant water status parameters such as LWP,RWC,volumetric moisture content(VMC),and leaf thickness were measured using standard methods.The results show that after 20 weeks of treatment,25%ER had the highest impedance value ranged from 0.10 MX to 0.15 MX at the frequency of 70–100 kHz.The resistance of 100%ER at 20 weeks of treatment increased from 0.70 kX to 1.23 kX as the reactance decreased from 0.51 kX to 0.28 kX.Comparatively,the resistance of 25%ER increased from 1 kX to 1.10 kX as the reactance decreased from 0.88 kX to 0.83 kX.The polynomial regression of impedance measurements with plant water status parameters(VMC,leaf thickness,LWP and RWC)shows that LWP and RWC had the highest R2(0.78,0.73).The results show that impedance measurement technique is auspicious to evaluate plant water status.
关 键 词:Impedance spectroscopy Plant water status Labisia pumila IMPEDANCE REACTANCE RESISTANCE
分 类 号:R54[医药卫生—心血管疾病]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.7