基于局部放电检测结果的高压开关柜绝缘改造  被引量:2

Insulation Modification of a High Voltage Switchgear Based on Partial Discharge Detection Results

在线阅读下载全文

作  者:柳强 莫小向 兰永林 刘健 LIU Qiang;MO Xiaoxiang;LAN Yonglin;LIU Jian(Hechi Power Supply Bureau,Guangxi Power Grid Co.,Ltd.,Guangxi Hechi 547000,China)

机构地区:[1]广西电网有限责任公司河池供电局,广西河池547000

出  处:《广西电力》2020年第6期76-80,共5页Guangxi Electric Power

摘  要:结合某110 kV变电站35 kV开关柜绝缘缺陷案例,采用局部放电检测方法证实了该开关柜存在局部放电问题,并采用紫外成像技术对缺陷进行定位,最后根据定位结果提出了开关柜绝缘改造方案。研究结果表明,通过局部放电检测能够有效地发现设备内部存在的放电缺陷,为绝缘改造提供可靠依据。Combined with a case of insulation defects in a 35 kV switchgear in a 110 kV substation,the partial discharge detection method was used to prove that the switchgear had partial discharge problems.The ultraviolet imaging technology was used to locate the defects.Finally,the insulation modification plan of the switchgear was proposed based on the location results.The research results show that the partial discharge detection can effectively find the discharge defects inside the equipment and provide a reliable basis for insulation modification.

关 键 词:高压开关柜 局部放电检测 绝缘改造 

分 类 号:TM591[电气工程—电器] TM855

 