检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:翟涵 谢华清 吴子华 张佳 Zhai Han;Xie Huaqing;Wu Zihua;Zhang Jia(School of Energy and Power Engineering,Nanjing University qf Science and Technology f Nanjing 210009,China;College of Environmental and Materials Engineering,Shanghai Polytechnic University,Shanghai 201209,China)
机构地区:[1]南京理工大学能源与动力工程学院,南京210009 [2]上海第二工业大学工学部环境与材料工程学院,上海201209
出 处:《太阳能学报》2021年第1期36-42,共7页Acta Energiae Solaris Sinica
基 金:国家自然科学基金重大项目(51590902)。
摘 要:通过对二线与四线接法测试单晶硅太阳电池I-V曲线的实验结果对比,分析串联内阻对于太阳电池短路电流、开路电压、填充因子及最大输出功率测量结果的影响。结果发现串联内阻越大,太阳电池的短路电流、填充因子及最大输出功率测量结果越小,但对开路电压基本无影响。且太阳电池接收光强越大即输出电流越大时,串联内阻的影响也越大。二线法因串联内阻较大,相较四线测量方法,在光强分别为1160.69、734.61、470.15和232.14 W/m^(2)时,最大功率降幅分别为64.73%、40.26%、22.98%、11.88%;填充因子降幅分别为64.10%、40.96%、22.22%、12.66%。表明内阻大小影响二线及四线测量结果,四线法测量方式能有效规避串联引线电阻和部分接触电阻,是较理想的测量方式。Photovoltaic parameters are significant standards for measuring the quality of solar cells. While the measurement result of photovoltaic parameters is influenced by the methods of measurement. The effect of series resistance on the photovoltaic short-circuit current,open-circuit voltage,fill factor and maximum power has been analyzed by measuring the I-V characteristics with 2-wires and4-wires in this study. The experiment was carried out employing solar cell simulator at constant light intensities 232.14-1160.69 W/m^(2) and using the vacuum thermostat to avoid the thermal convection. The results show that the measurement of short-circuit current fill factor and maximum power would decrease with increasing of series resistance. While the open-circuit is not influenced by the series resistance. In addition the effect of series resistance will be more powerful when the light intensity increasing. The measurement of 2-wires has higher seriesresistancethan 4-wires. At light intensity of 1160.69,735.61,470.15 and 232.14 W/m^(2) the maximum power of 2-wires measurement would decrease by 64.73%,40.26%,22.98% and 11.88% than 4-wires measurement. Meanwhile,the fill factor of 2-wires measurement would decrease by 64.10%,40.96%,22.22% and 12.66% than 4-wires measurement. So the measurement of photovoltaic parameters is affectedbyseriesresistance. And the 4-wires measurement is more excellent than 2-wires because of lower series resistance.
分 类 号:TK51[动力工程及工程热物理—热能工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.147.74.90