检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:李国庆[1] 杨勇[1] 辛业春 江守其 王拓 LI Guoqing;YANG Yong;XIN Yechun;JIANG Shouqi;WANG Tuo(Key Laboratory of Modern Power System Simulation and Control&Renewable Energy Technology(Northeast Electric Power University),Ministry of Education,Jilin 132012,Jilin Province,China)
机构地区:[1]现代电力系统仿真控制与绿色电能新技术教育部重点实验室(东北电力大学),吉林省吉林市132012
出 处:《电网技术》2021年第1期144-152,共9页Power System Technology
基 金:国家电网公司总部科技项目(5102-201999343A-0-0-00)。
摘 要:基于模块化多电平换流器(modular multilevel converter,MMC)的柔性直流输电系统直流短路后电流上升迅速且伴随大量的能量释放,为限制其故障电流,提出一种基于桥臂电压控制的MMC主动限流方法。根据故障电流影响因素分析,针对不同交流出口特性需求,设计了故障期间桥臂电压控制方法,通过减小桥臂电压直流分量降低直流出口电压,从而抑制故障电流上升率;考虑主动限流策略对交流电压及桥臂电流的影响,以MMC不闭锁为约束条件,设计了控制参数的选取原则,最后在四端直流电网中对该主动限流方法的限流效果及其对故障切除后功率恢复的影响进行了仿真分析。结果表明,所提主动限流方法能够有效限制短路电流,降低直流断路器的电流开断难度,且对故障切除后的功率恢复影响较小。The DC fault current of the voltage source converter HVDC(VSC-HVDC) based on MMC rises rapidly with accompanying high fault energy. In order to handle DC short-circuit in a VSC-HVDC system, an active current-limiting method of MMC based on the bridge arm voltage control is proposed. By analyzing influence factors of the fault current, the bridge arm voltage control is designed for different needs of AC system. And the DC component of the bridge arm voltage is cut down to reduce the DC voltage of MMC, then the fault current is limited. Considering the influence of the active current-limiting method on AC voltage and bridge arm currents, the selection principle of the control parameters is designed on the premise that MMC will not block. Finally, current-limiting effects of the active current-limiting method and its influence on power recovery after fault clearance are simulated and analyzed in four terminal DC grids. And the results show that the proposed method can limit the short-circuit current effectively, which alleviates the difficulty of DC circuit breaker on fault clearance and causes little effects on power recovery.
关 键 词:MMC 直流故障 直流电网 电流上升率 主动限流
分 类 号:TM721[电气工程—电力系统及自动化]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.7