检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:刘朝阳 赵方 栾大伟 李雅慧 刘萍 卢晋英[3] LIU Chaoyang;ZHAO Fang;LUAN Dawei;LI Yahui;LIU Ping;LU Jinying1((Tianjin) Diagnostic Technology Co.,Ltd.,Tianjin 300300,China;Tianjin Enterprise Key Laboratory,Chemiluminescence and POCT Diagnostic Technology,Tianjin 300300,China;Tianjing Third Central Hospital,Tianjin 300000,China)
机构地区:[1]博奥赛斯(天津)生物科技有限公司,天津300300 [2]天津市化学发光与快速诊断分析技术企业重点实验室,天津300300 [3]天津市第三中心医院,天津300000
出 处:《国际检验医学杂志》2021年第6期725-728,733,共5页International Journal of Laboratory Medicine
基 金:艾滋病和病毒性肝炎等重大传染病防治专项项目(2018ZX10732202)。
摘 要:建立一种荧光定量层粘连蛋白(LN)检测方法,定量检测人血清LN水平。将鼠抗LN抗体用划线机喷到硝酸纤维素膜表面作为检测线(T),将链霉素亲和素用划线机喷到硝酸纤维素膜表面作为质控线(C);用生物素荧光微球标记鼠抗LN抗体作为缓冲液。利用双抗体夹心法原理定量检测LN水平,对方法的线性、精密度、空白限、回收率、相关性等性能指标进行验证,并使用市售化学发光LN试剂盒比对。荧光免疫分辨检测LN方法的回收率为86.03%~97.50%,空白限为4.22 ng/mL,线性范围为20~800 ng/mL,相关系数(r)为0.9989;批内精密度为6.51%,批间精密度为6.23%。与市售LN试剂平行检测100份血清标本,有良好的相关性(Y=1.0219X-1.1720,r=0.9871)。本研究建立了LN荧光免疫检测方法,各项性能指标均达到临床检验要求,操作便捷、结果准确,可用于临床血清LN水平的检测。To establish a quantitative detection method for Laminin(LN)based on Time-Resolved Fluorescence Immunoassay.The mouse anti-LN antibody was sprayed onto the surface of the nitrocellulose membrane with a marking machine as the detection line(T).Streptomycin avidin was sprayed onto the surface of cellulose nitrate membrane by marking machine as the quality control line(C).Mouse anti LN antibody was labeled with biotin fluorescent microspheres as buffer.The LN was quantitatively detected by the double antibody sandwich method,the linearity,precision,limit of blank,recovery and correlation of the method were verified,and the commercial chemiluminescence LN kit was used for comparison.The recovery of the fluorescence immunoassay for LN was 86.03%-97.50%.The limit of blank of LN was 4.22 ng/mL,the linear range was 20-800 ng/mL,the correlation coefficient r was 0.9989,the within-run precision was 6.51%,and the between-run precision was 6.23%.Compared with the commercially available product(100 serum samples),LN showed the high consistency(Y=1.0219X-1.1720,r=0.9871).In this study,the fluorescence immunoassay detection method of LN was established.All the performance indexes met the requirements of clinical examination.It was easy to operate and accurate,and could be used for the detection of serum LN level in clinic.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.139.64.42