一起循环水量不足造成机组低真空保护动作跳闸原因分析  被引量:2

Analysis of Low Vacuum Protection Trip Caused by Insufficient Circulating Water

在线阅读下载全文

作  者:李衍平 LI Yanping(Huadian International Laicheng Power Plant,Jinan,Shandong 271100,China)

机构地区:[1]华电国际莱城发电厂,山东济南271100

出  处:《东北电力技术》2021年第2期50-52,共3页Northeast Electric Power Technology

摘  要:循环水泵是循环冷却水系统的重要设备之一,该设备正常运行与否直接关系到机组安全运行。在循环水泵定期切换工作中,由于循环水泵出口蝶阀运行状态不正常,容易发生故障停机情况,从运行和检修两方面把关,切实保证了循环水泵及机组稳定可靠运行。The circulating water pump is one of the important equipment of the circulating cooling water system.The normal operation of the equipment is directly related to the safe operation of the unit.In the regular switching work of circulating water pump,due to the abnormal state of butterfly valve at the outlet of circulating water pump,it is easy to cause the loss of circulating water and the occurrence of fault shutdown.The stable and reliable operation of circulating water pump is guaranteed and the safe operation of the unit is guaranteed by the two aspects of operation and maintenance.

关 键 词:循环水泵 定期工作 出口蝶阀 电流 

分 类 号:TM621[电气工程—电力系统及自动化]

 