检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:黄杰 HUANG Jie(Maintenance Branch of State Grid Jiangsu Electric Power Co,Ltd.,Huai'an,Jiangsu Province,223000 China)
机构地区:[1]国网江苏省电力有限公司检修分公司,江苏淮安223000
出 处:《科技创新导报》2020年第36期119-121,共3页Science and Technology Innovation Herald
摘 要:本文主要针对一起因电子元件损坏导致的500kV西门子3AT3EI型高压断路器合闸故障进行分析研究。根据现场故障现象,本文通过对该断路器的合闸控制回路和相应的闭锁控制回路进行仔细分析推导,寻找出故障发生真正原因,并根据故障原因提出相应的防范措施,为避免同类断路器设备此类故障再次发生提供借鉴,切实提高超高压电网设备的运行可靠性。This paper mainly a nalyzes a closing fault of 500kV Siemens 3AT3EI high voltage circuit breaker caused by electronic component damage.According to the on-site fault phenomenon,this paper analyzes and deduces the closing control circuit and the corresponding locking control circuit of the circuit breaker,finds out the real cause of the fault,and puts forward corresponding preventive measures according to the fault causes,so as to provide reference for avoiding similar circuit breaker equipment from happening again,and effectively improve the operation reliability of ultra-high voltage power grid equipment.