摘  要:针对一起高压加热器泄漏引起的汽轮机保护动作事件,分析了原因,指出了暴露的问题,采取了更换高压加热器泄漏管束,完善高压加热器系统和保护逻辑等防范措施。实践证明,及早发现并正确处理高压加热器泄漏,既避免了事故扩大,又保证了机组效率。In allusion to an accident of steam turbine protection action caused by the leakage of a high-pressure heater,the causes are analyzed,and the exposed problems are pointed out.The preventive measures such as replacing the leakage tube bun⁃dle of the high-pressure heater,improving the high-pressure heater system and protection logic are put forward.It is proved by practice that if the leakage of a high-pressure heater can be detected and handled correctly as soon as possible,it could avoid the expansion of the accident and also ensure the efficiency of the unit.