一起电缆终端接头故障仿真分析研究  被引量:3

Simulation Analysis and Research on a Cable Terminal Joint Failure

在线阅读下载全文

作  者:向洪 何维晟 吴照国 邓帮飞 张海兵 王谦 任啸 XIANG Hong;HE Weisheng;WU Zhaoguo;DENG Bangfei;ZHANG Haibing;WANG Qian;REN Xiao(State Grid Chongqing Power Research Institute,Chongqing 400022,China)

机构地区:[1]国网重庆市电力公司电力科学研究院,重庆400022

出  处:《电工技术》2021年第3期139-140,143,共3页Electric Engineering

摘  要:电缆附件的用量随着我国城市电缆网络的发展得到了越来越广泛的使用,然而电缆附件由于制作工艺或运行环境的影响,故障率仍居高不下。分析了一起由工艺质量引起的电缆终端接头故障,解剖后发现半导电层具有较多的凸起和尖刺,随后通过有限元仿真软件建立电缆终端模型,仿真分析了半导电层无凸起、存在凸起及存在凸起且伴随气隙时的最大电场强度,得出在半导电层制作工艺不良产生凸起的情况下会引发局部放电,最终导致终端击穿故障。The amount of cable accessories has been more and more widely used with the development of urban cable networks in my country.However,the failure rate of cable accessories is still high due to the influence of manufacturing process or operating environment.A cable terminal joint fault caused by process quality was analyzed.After dissection,it was found that the semi conductive layer had more bulges and spines.Then,the cable terminal model was established by finite element simulation software,and the maximum electric field strength of the semi-conductive layer without bumps,bumps,and bumps with air gaps was simulated and analyzed.It was concluded that when the semi-conductive layer was poorly fabricated and bumps were generated,partial discharges would be triggered,which would eventually lead to terminal breakdown.

关 键 词:配电电缆 终端接头 局部放电 半导电层 

分 类 号:TM75[电气工程—电力系统及自动化]

 