Rotarex经皮机械血栓清除术联合药物涂层球囊治疗股腘动脉支架内再狭窄  被引量:7

Rotarex percutaneous mechanical thrombectomy combined with drug coated balloon for treating in-stent restenosis of femoropopliteal artery

在线阅读下载全文

作  者:王广华[1] 王兵[1] 崔文军[1] 司江涛[1] 王颖[1] WANG Guanghua;WANG Bing;CUI Wenjun;SI Jiangtao;WANG Ying(Department of Vascular Surgery, the Fifth Affiliated Hospital, Zhengzhou University, Zhengzhou 450052, China)

机构地区:[1]郑州大学第五附属医院血管外科,河南郑州450052

出  处:《中国介入影像与治疗学》2021年第3期137-141,共5页Chinese Journal of Interventional Imaging and Therapy

基  金:河南省医学科技攻关计划项目(LHGJ20190420);河南省高等学校重点科研项目(16B320023)。

摘  要:目的观察Rotarex经皮机械血栓清除术(PMT)联合药物涂层球囊(DCB)治疗股腘动脉支架内再狭窄的效果。方法回顾性分析26例接受Rotarex PMT联合DCB治疗的股腘动脉支架内再狭窄患者,评价治疗效果,统计并发症。结果26例手术均成功,随访期间无死亡或截肢,围手术期不良反应发生率为7.69%(2/26)。术后1周Rutherford临床分级较术前降低(P=0.012)。术后3、6、12个月踝肱指数(ABI)、间歇性跛行均较术前明显改善(P均<0.05)。术后6、12个月靶血管一期通畅率分别为96.15%(25/26)、84.62%(22/26),12个月免于靶血管血运重建(f-TLR)率为88.46%(23/26)。结论Rotarex PMT联合DCB治疗股腘动脉支架内再狭窄安全、有效。Objective To explore the effect of Rotarex percutaneous mechanical thrombectomy(PMT)combined with drug-coated balloon(DCB)in treatment of in-stent restenosis of femoropopliteal artery.Methods Data of 26 patients with in-stent restenosis of femoropopliteal artery who underwent Rotarex PMT combined with DCB treatment were retrospectively analyzed.The therapeutic effect was evaluated,and complications were counted.Results Rndovascular procedures were successfully performed in all 26 patients.No death nor amputation occurred during the follow-up period,and the incidence of perioperative adverse events was 7.69%(2/6).One week after operation,Rutherford clinical grade decreased compared with that before operation(P=0.012).The ankle brachial index(ABI)and distance of intermittent claudication 3,6,12 months after operation were significantly higher than those before operation(all P<0.05).The postoperative vascular patency rate of 6,12 months was 96.15%(25/26)and 84.62%(22/26),respectively.The rate of freedom from target revascularization(f-TLR)of postoperative 12 months was 88.46%(23/26).Conclusion Rotarex PMT combined with DCB was safe and effective in treatment of in-stent restenosis of femoropopliteal artery.

关 键 词:外周血管疾病 股动脉 腘动脉 血管成形术 球囊 机械取栓 

分 类 号:R658.3[医药卫生—外科学] R815[医药卫生—临床医学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象