检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:余丰文[1] 刘德军[1] 杨明[1] 鲁胜男[1] 王颖[1] 冯彦林[1] YU Fengwen;LIU Dejun;YANG Ming;LU Shengnan;WANG Ying;FENG Yanlin(Department of Nuclear Medicine,First People's Hospital of Foshan,Foshan 528000,China)
机构地区:[1]佛山市第一人民医院核医学科,广东佛山528000
出 处:《中国医学影像学杂志》2021年第3期201-206,共6页Chinese Journal of Medical Imaging
基 金:佛山市科技创新专项资金(2015AG10009)。
摘 要:目的探讨继发甲状旁腺功能亢进症的术前影像学定位诊断价值。资料与方法纳入60例手术成功(20 min术中甲状旁腺激素下降≥80%)的慢性肾病继发甲状旁腺功能亢进症,以病理诊断为“金标准”,采用McNemar检验比较^(99)锝^(m)-甲氧基异丁基异腈(^(99)Tc^(m)-MIBI)SPECT/CT、双时相平面显像、彩色多普勒超声联合应用术前定位甲状旁腺组织的敏感度、特异度和准确度。结果60例患者共243个甲状旁腺灶和36个非甲状旁腺灶。术前SPECT/CT定位甲状旁腺的敏感度、特异度和准确度分别为85.60%(208/243)、94.44%(34/36)和86.74%(242/279),其敏感度和准确度均优于平面显像[敏感度53.50%(130/243),P<0.001;准确度57.35%(160/279),P<0.001]、超声[敏感度53.09%(129/243),P<0.001;准确度56.63%(158/279),P<0.001]及平面显像+超声联合模式[敏感度71.19%(173/243),P<0.001;准确度70.61%(197/279),P<0.001]。SPECT/CT联合超声可使敏感度提高至86.01%(209/243)。结论继发甲状旁腺功能亢进症术前^(99)Tc^(m)-MIBI SPECT/CT定位甲状旁腺组织具有较高的敏感度和准确度,联合超声能进一步提高检出敏感度,并能发现更多的伴发甲状腺疾病。Purpose To investigate the value of preoperative imaging location for secondary hyperparathyroidism(sHPT).Materials and Methods Sixty patients with chronic kidney disease combined with sHPT on hemodialysis were included in this study.All were performed total parathyroidectomy with autotransplantation,and 80%or more declined intra-operative parathyroid hormone at 20 minutes was considered successful.Preoperative color Doppler ultrasonography(CDUS),^(99)Tc^(m)-sestamibi(MIBI)dual-phase planar,hybrid SPECT/CT delayed scintigraphy were used to identify parathyroid lesions.Surgical pathological diagnosis served as the standard,the sensitivity,specificity and accuracy were determined and compared using McNemar test.Results There were 243 parathyroid positive lesions and 36 false-positive lesions in 60 sHPT patients.The sensitivity,specificity and accuracy of SPECT/CT was 85.60%(208/243),94.44%(34/36)and 86.74%(242/279),respectively.The sensitivity and accuracy of SPECT/CT were significantly better than that of planar imaging[53.50%(130/243),P<0.001 for sensitivity;57.35%(160/279),P<0.001 for accuracy],CDUS[53.09%(129/243),P<0.001 for sensitivity;56.63%(158/279),P<0.001 for accuracy]and planar imaging+CDUS[71.19%(173/243),P<0.001 for sensitivity;70.61%(197/279),P<0.001 for accuracy].The sensitivity increased to 86.01%(209/243),and more concomitant thyroid diseases were found by combining with CDUS.Conclusion^(99)Tc^(m)-MIBI SPECT/CT has higher sensitivity and accuracy for preoperative localization parathyroid of sHPT patients,the sensitivity can be increased and more concomitant thyroid diseases can be found when combined with CDUS.
关 键 词:甲状旁腺疾病 肾功能衰竭 慢性 体层摄影术 发射型计算机 单光子 超声检查 多普勒 彩色 ^(99)锝^(m)-甲氧基异丁基异腈 病理学 外科
分 类 号:R445.5[医药卫生—影像医学与核医学] R582[医药卫生—诊断学]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.222