检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:贾伯岩 张鹏 张媛媛[3] 徐亚兵 魏力强 JIA Bo-yan;ZHANG Peng;ZHANG Yuan-yuan;XU Ya-bing;WEI Li-qiang(State Grid Hebei Electric Power Research Institute,State Grid Hebei Electric Power Co.Ltd.,Hebei Shijiazhuang 050021,China;China University of Mining and Technology,Jiangsu Xuzhou 221116,China;State Grid Hebei Electric Power Co.Ltd.,Hebei Shijiazhuang 050021,China)
机构地区:[1]国网河北省电力有限公司电力科学研究院电力设备技术中心,河北石家庄050021 [2]国网河北省电力有限公司电力科学研究院,河北石家庄050021 [3]中国矿业大学,江苏徐州221116 [4]国网河北省电力有限公司,河北石家庄050021
出 处:《消防科学与技术》2021年第1期47-50,共4页Fire Science and Technology
基 金:国家电网公司总部科技项目“新型变电站电缆和沟道火灾预警及防火灭火技术研究”(5200-201932093A-0-0-00)。
摘 要:以某综合管廊为研究背景,利用PyroSim模拟软件建立的仿真计算模型,研究了设立挡烟垂壁、改变防火门开启程度、增设排烟设施等情况下的烟气蔓延规律。研究发现:在烟气未充满管廊时,挡烟垂壁会使烟气蔓延速度降低,烟气蔓延速度与挡烟垂壁高度成反比;防火门打开会使火灾烟气蔓延至相邻防火分区,烟气蔓延速率与防火门开启程度成正相关;机械排烟设施会使烟气蔓延速度显著降低,最高降低约50%,当烟气完全充满整个管廊时,会显著降低综合管廊内烟气浓度,烟气层温度最高降幅32℃,能见度最高增加了66%。通过对综合管廊内烟气蔓延的研究,探寻防治综合管廊烟气蔓延的最佳措施,为综合管廊烟气防治的实际工程应用提供参考。Taking utility tunnel as the research background,a simulation calculation model for fire smoke prevention and control in the utility tunnel was built by PyroSim numerical simulation software and the rules of smoke spread under conditions such as building ceiling screen,changing fire compartmentation tightness,and adding smoke exhaust facilities were explored.According to study results,before the tunnel was filled with smoke,ceiling screens lowered smoke spread rate,and smoke spread rate was inversely proportional to ceiling screen height.When the fire door was opened,fire smoke spread to the adjacent fire compartment,and smoke spread rate was directly proportional to the fire door opening angle.Mechanical smoke exhaust facilities significantly lowered the smoke spread rate by as much as 50%.When the entire tunnel was full of smoke,mechanical smoke exhaust facilities reduced the smoke concentration in the utility tunnel significantly.Smoke layer temperature dropped by as much as 32℃,while visibility improved by as much as 66%.By studying smoke spread in utility tunnel,this paper aims to determine the optimal measures of preventing and controlling smoke spread in utility tunnel.This paper could also provide reference for practical engineering applications in smoke prevention and control in utility tunnel.
分 类 号:X924.4[环境科学与工程—安全科学] TU998.1[建筑科学—市政工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.117